15
8.
When “AOUT” is displayed, press SYS to return to RUN mode.
For analog outputs 4, 5, and 6, your entries will be shown on the bottom display.
Name
Parameter Description
NH3R
NH
3
before the addition of Delta NH3 Table (ppm)
CEL1
Cell 1 voltage (mV)
CEL2
Cell 2 voltage (mV)
RPVS
NH
3
sensor internal Vs cell resistance (Ohms)
VHCM
Desired heater voltage commanded by the module (V)
VS
NH
3
sensor internal Vs cell voltage
VSW
Supply voltage at the module (V)
VH
Actual heater voltage at the module (V)
TEMP
Temperature of the module circuit board (deg C)
C1R
Cell 1 raw bits (bits)
C2R
Cell 2 raw bits (bits)
ERFL
Module error flags (unsigned long format)
ERCd
ECM CANOpen Error Code (unsigned integer)
PR10
10 bit Pressure sensor output voltage (unsigned integer format)
P
Pressure sensor measured pressure (absolute) in mmHg
MODE
NH
3
measurement mode (hex)
RCL
NH
3
cal constant (no units)
SCF
NH
3
scale factor (no units)
NH3
NH
3
after addition of Delta NH3 Table (ppm)
PVLT
Raw volts from pressure sensor (V)
PKPA
Pressure sensor measured pressure (absolute) in kPa
PBAR
Pressure sensor measured pressure (absolute) in bar
PPSI
Pressure sensor measured pressure (absolute) in psi
Table 2: Parameter List for the NH
3
5250