ENGLISH
Translation of the original German user manual
32
4
Clamp the portafilter into the brew group.
5
Operate the group lever. The blind filter will fill with water.
6
Let the detergent react, moving the group lever into the middle position, approx. 45°. (Do not move it into
the lower position.)
7
Move the lever into the lower position after approx. 20 seconds. This way, the fats and oils can be
discharged by the infusion cylinder.
8
Repeat points 5-7 several times, until only clear water is discharged by the infusion cylinder.
9
Rinse the portafilter and the blind filter with fresh water. Then replace it.
10
Operate the group lever for approx. 40 seconds. Then move it back into the lower position.
11
Remove the portafilter and repeat point 10. After this, the brew group is ready for use.
12
Place the filter for 1 or 2 cups into the portafilter.
Caution!
Beware of hot spray while cleaning the group.
To stow away the blind filter,
you will find under the drip tray,
at the rear left, a mounting bracket
therefor
In case you progra
mmed the cleaning mode, the“CLn” wi
ll disappear on the display after
having operated the brew group lever 10 times. The counter will then restart until the next
cleaning advice.
If you clean the brew group to often with cleaner, it may start squeaking. Don´t clean it to
often with cleaner, you will degrease all the moving parts and they will wear out quickly. It´s
better if you clean the brew group from time to time without cleaner.
7.3 Maintenance
Caution!
Make sure that the machine is disconnected from the mains during maintenance and
when replacing individual parts.
Replacing the group gasket and the shower screen
1
Switch off the machine (power switch in position“0”) and disconnect the
power cord.
2
Let the machine cool down to room temperature.
Follow the steps as indicated below:
1
Brew group in the beginning.
2
Use a flat screwdriver to pry out
the shower screen and the group
gasket.
3
The shower screen and the
gasket are now nearly removed.