We recommend
a temperature setting on the PID of 124°C at about 1.25 bar, which corresponds to an outlet
temperature of about 94°C (121°F). If the temperature is set lower, there will not be enough pressure to foam
milk
Please note that after changing the steam temperature on the display, it takes a certain
amount of time for the corresponding temperature to be reached on the brewing group.
To adjust the temperature please follow the instructions below:
1
Switch the machine on in order to activate the boiler. The temperature
of the boiler is of no importance in programming. The heater is
inactive during programming.
2
Press
–
and
+
at the same time until ‘t1’ (boiler) appears on the
display,
3
Press
+
in order to progress to the submenu of ‘t1’ and to change the
temperature value. The nominal temperature value is displayed.
4
Quickly press
–
to decrease
+
to increase
the temperature value.
5
Please wait a short while after having set the temperature ;
until ‘t1’ is displayed.
6
Press
–
to leave the programming mode.
6.3.2
Programming the Temperature Mode “o”
You can also set whether the temperature value of
“t1”
should be displayed in °C or °F.
To adjust this setting, proceed as follows:
1
Press
+
and
–
at the same time and “t1” will appear on the display.
2
Press the button
–
twice. After t1, "o" appears on the display.
Press
+
to enter the menu.
3
Now you can choose between C for Celsius and F for Fahrenheit by
pressing
–
. This will also set t2.
4