Section 9. Climate Control
Eclipse 5OO Systems Manual
Copyright
© — Eclipse Aviation Corporation
Version 2.0 April 2007
191
9.4.4 Pressurization Synoptic
Figure 123.
Pressurization Synoptic
Pressurization system control, including modes of operation and selection of air
distribution is provided on the pressurization (PRESS) synoptic. The LDG ALT,
CABIN ALT, and CABIN RATE functions are controlled by the concentric MFD knobs.
While in MANUAL mode of operation, rotate the outer portion of the concentric MFD
knob to select the function to be controlled.
(The blue box steps through the three boxes.) Rotate the inner portion of the MFD
knob to desired setting.
Table 24. Pressurization Synoptic Indications
Pylon Temperature
Temperature in pylon
Flow Control Valve Setting
HIGH or LOW flow
Duct Temperature
Bleed air temperature downstream of
heat exchanger
Isolation/Cabin Shutoff Valves
Position of isolation and cabin air shutoff
valve