10
Keys A and B and briefly pressing the rotary encoder knob do not work
when the unit is in a mode other than ZONES mode, given that
adjustments in these other modes will be shared by both outputs
o
VOL + and - keys in the ZONE section: the MASTER volume of the
previously-selected zone increases/decreases by pressing the keys.
This works the same as turning the unit's front rotary encoder knob in
default operation mode. Pressing and holding these keys increases or
decreases the volume continuously.
o
MUTE key: activates/deactivates the full silence of the previously-
selected zone
o
LINE keys 1 to 4: enable selecting/deselecting a LINE source as active
for the previously-selected zone (the same as the LINE1 to LINE4 keys
on the front panel)
o
VOL + and - keys in the LINE section: the volume of the previously-
selected source for the likewise previously-selected zone
increases/decreases with each press of the key. A single source has
independent volume adjustments for sending to zones A and B when
operating in ZONES mode (example: the LINE1 source can be sent with
volume of 50 to zone A and at a volume of 62 to zone B, etc.). If no
LINE is selected, these controls are not operative, and the LCD screen
displays the message "LINE NOT SELECTED"
o
MIC1/MIC2 keys: enable selecting/deselecting a MIC source as active
for the previously-selected zone (the same as the MIC1 and MIC2 keys
on the front panel)
o
VOL + and - keys in the MIC1 or MIC2 section: the volume of the MIC
source in question for the previously-selected zone increases/decreases
with each press of the key. A single microphone source has
independent volume adjustments for sending to zones A and B when
operating in ZONES mode (example: MIC1 can be sent at a volume of
35 to zone A and at a volume of 57 to zone B, etc.)
o
PRESET keys: enable recovering one of the CA200z 5 presets or
configuration memories. These keys must be held down for a few
seconds to recover the preset in question, while the active preset is
displayed on the LCD screen as P1, P2, P3, P4 or P5
o
ON/STBY key: Enables changing from STANDBY mode to ON mode
and vice versa. To change from ON to STANDBY, this key must be
pressed and held for a few moments
Note:
The first time a key that actuates in timed mode is pressed (PRESET 1-5 and ON/STBY), it
wakes up the LCD panel if it is off, in attenuated inactivity in the DIMMED or OFF modes, or if the
CA200z is in AUTO STAND BY mode. If the key is held down (long pulsation) or released and
pressed again, the CA200z will execute the associated function.
Summary of Contents for CA200z
Page 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D UTILISATION BEDIENUNGSANLEITUNG CA200z ...
Page 23: ...23 7 DIAGRAM OF FUNCTIONS ...
Page 45: ...45 7 DIAGRAMA DE FUNCIONES ...
Page 67: ...67 7 SCHÉMA DE FONCTIONS ...
Page 89: ...89 7 FUNKTIONSDIAGRAMM ...
Page 91: ...91 9 BLOCK DIAGRAM 9 DIAGRAMA DE BLOQUES 9 SCHÉMA FONCTIONNEL 9 BLOCKSCHALTBILD ...