Processing available for outputs: 

o

 

Mono mode (outputs managed individually) or stereo mode (outputs 

managed  in  natural  pairs):  1-2,  3-4,  etc.).  Automatic  handling  of 
mono  or  stereo  audio  sources  routed  towards  mono  or  stereo 

outputs. 

o

 

Selection of program source (local or remote audio inputs) 

o

 

3-band EQ adjustment via BASS-MID-TREBLE controls. 

o

 

Volume adjustment and MUTE control. 

o

 

Limitation  on  available  output  volume  range  (minimum  and 

maximum  levels)  for  end  user,  from  any  method  of  control 

(eMCONTROL1 panels, client pilot application, etc.) 

o

 

Phase inversion 

o

 

Enablement for muting via MUTE port on rear panel (via closing of 

external contact) 

 

Programming  and  control  as  Administrator  (

admin

)  via  the 

embedded 

web application

, using a computer, tablet or mobile device, and a standard 

web browser (without the installation of dedicated software) 

 

Remote control for end users via: 

o

 

Front control panel, with programmable access restrictions 

o

 

eMCONTROL1 physical wall panels 

o

 

eMPAGE (paging) messaging consoles 

o

 

eMIMO pilot

 application, available for iOS and Android devices 

o

 

Standard web browsers, via computers, tablets, etc. 

 

Note:

  from  the  unit's  embedded  web  application,  the 

admin

  user  can  set 

restrictions  on  controls  and  adjustments  available  from  the  physical  wall  panels 
(eMCONTROL1) and messaging consoles (eMPAGE) for the end user, together with 
user  accounts  and  the  graphic  control  and  adjustment  panels  that  the  end  users 
can use via the 

eMIMO pilot

 and web applications. 

 

 

Summary of Contents for eMIMO1616

Page 1: ...eMIMO1616 DIGITAL MATRIXES Digital audio matrix 16x16 USER MANUAL ...

Page 2: ... 10 5 4 Remote audio input connections 12 5 5 PAGER A PAGER B connections and priority PAGER DUCKER modules 13 5 6 REMOTE INPUTS 1 to 8 connections 15 5 7 Audio output connections 16 5 8 ETHERNET and RS 232 ports for programming and control 17 5 9 MUTE port 18 6 CONFIGURATION AND CONTROL 18 6 1 Configuration via embedded web application 18 6 2 Front panel control 20 7 FUNCTION LIST 24 8 FUNCTION D...

Page 3: ...risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a ...

Page 4: ... at the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug the apparatus during lightening sorts or when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects ha...

Page 5: ...n accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING This product must not be discarded under any circumstance as unsorted urban waste Take to the nearest electrical and el...

Page 6: ...s Android iOS Main features include 4 local inputs for stereo audio compatible with line levels and gain adjustment from 6 to 16 dB 2xRCA and Euroblock connectors on rear panel INPUT 1 to INPUT 4 4 local inputs for mono audio compatible with microphone and line levels gain adjustment from 0 to 50 dB Euroblock connectors on rear panel INPUT 5 to INPUT 8 8 remote inputs for balanced mono audio compa...

Page 7: ...anel Processing available for inputs o 3 band EQ adjustment via BASS MID TREBLE controls o Volume adjustment and MUTE control o Phase inversion o Noise gate available for INPUT 5 to INPUT 8 local inputs o Variable frequency high pass filter available for INPUT 5 to INPUT 8 local inputs o Audio over audio priority function with two levels inputs 5 to 8 MIC LINE can fade or mute fully the sound cont...

Page 8: ...contact Programming and control as Administrator admin via the embedded web application using a computer tablet or mobile device and a standard web browser without the installation of dedicated software Remote control for end users via o Front control panel with programmable access restrictions o eMCONTROL1 physical wall panels o eMPAGE paging messaging consoles o eMIMO pilot application available...

Page 9: ...vision of upward forced ventilation through the fitting of fans on the lower and upper extremes is highly recommended The upward ventilation flow will improve the dissipation of heat generated within 5 2 Connection to the mains supply and switching on The eMIMO1616 is powered by an AC voltage of 90 to 264V at 47 to 63Hz The unit features an overdimensioned power supply unit capable of adapting to ...

Page 10: ...le RCA connector connect the stereo sound source directly CD players Smart phones radio tuners streaming players etc via a cable that delivers the left L channels and right R channels to the white and red RCA connectors on the unit respectively o Euroblock connector 3 contacts connect the stereo sound source in this way Left channel L Terminal Right channel R Terminal Earth Terminal INPUT 5 to INP...

Page 11: ...e remote DC supply for the messaging console control data and balanced audio from the messaging console microphone can be transmitted The maximum number of messaging consoles allowed is 2 one connected to the PAGER A port and the other to the PAGER B port Once the physical connections for the various audio inputs have been made it will be necessary to adjust the GAIN control for each of them in or...

Page 12: ...addition to providing the DC power supply and digital communication bus for the remote panels has a balanced mono audio input with line level taken as a remote input for the eMIMO1616 unit It is thus possible to increase the number of audio inputs for the unit using these 8 remote inputs in addition to the 8 local inputs available via audio connectors on the rear panel of the matrix ...

Page 13: ... is ideal for remote control of the zone and audio from the zone itself a single CAT5 standard cable is connected between the eMCONTROL1 panel and a REMOTE port on the eMIMO1616 unit to provide the DC power supply transmit digital control data and send remote audio signals from a physical input on the eMCONTROL1 complementary panel to the eMIMO1616 unit 5 5 PAGER A PAGER B connections and priority...

Page 14: ...ing a PAGER priority module on the eMIMO1616 unit Note it is it not possible to perform the following connections simultaneously and the connections listed below are mutually exclusive a messaging console to the PAGER A port an audio signal to the INPUT7 Euroblock connector a messaging console to the PAGER A port an audio signal to the INPUT7 Euroblock connector The total number of PAGER to messag...

Page 15: ...e control panel on the eMIMO1616 unit The wall control panels are configured by the Administrator user via the eMIMO1616 web application see web application manual for the eMIMO1616 so that it is possible to fully disable them or enable them to function as user controls for an installation zone including all or some of the following functions Selection of sound source program audio from a customis...

Page 16: ... point between the two units In the event of connecting an output channel to an amplifier or device with an unbalanced audio input do not connect the terminal MONITOR output marked with a headphones symbol 3 5mm stereo mini jack connector with rotary level control to listen via headphones It is particularly useful for listening to output signals from the unit without disturbing its normal operatio...

Page 17: ...blets etc The connection of third party equipment for integration within control systems Crestron Extron AMX Vity Medialon etc brands registered by their manufacturers using the TP NET protocol embedded in the eMIMO1616 See the TP NET protocol manual for further information The DB9 RS 232 connector on the rear panel allows the connection of the unit point to point to a computer or other control de...

Page 18: ...ion 6 CONFIGURATION AND CONTROL 6 1 Configuration via embedded web application Once the physical connections have been made the eMIMO1616 must be configured via the embedded web application from a computer tablet or similar device on which it is possible to open a standard web browser connected to the IP address of the unit by default 192 168 0 100 but may be changed This task is reserved exclusiv...

Page 19: ...status etc Management of user accounts which will allow access to external clients end users via the eMIMO pilot application or web browsers names passwords and enabled disabled status Front panel parameters o adjustments to LCD screen brightness contrast stand by mode o overall access blocking for all front controls o individual access blocking for specific controls and for specific output zones ...

Page 20: ...rance control types slider or rotary control colours texts and background etc 6 2 Front panel control Using the physical controls on the front panel of the eMIMO1616 it is possible to make adjustments to the various output zones from the unit The settings available for the various zones will be those that the admin user enabled via the web application and may range from blocking the entire front p...

Page 21: ...r First line of text output number zone selected Second line of text name tag for the selected zone SRC selected sound source VOL set output volumen The flashing box above SRC or VOL in addition to the line of text in bold on a light background indicate which function is at that moment focussed or ready for setting The lower image shows the VOL control which allows adjustment of the output volume ...

Page 22: ...y changes the focus to the other available function in this case to the SRC function or the sound source selection Then turning the encoder allows the selection of one of the available sound sources with confirmation of selection by pressing the encoder A long press of the CTRL key jumps to the equalisation screen for the zone On the screen the selected tone control is indicated by the flashing re...

Page 23: ...hown and available for adjustment only if the admin user has enabled the front panel for this and a zone may be partially or fully blocked for control via the front panel When a specific function for a zone is disabled for adjustment via the front panel if this adjustment is attempted the following message will appear on the LCD screen When the front panel is fully blocked disabled for use on pres...

Page 24: ...orts connection to eMCONTROL1 15 RJ 45 connector ETHERNET 16 Remote PAGER ports connection to eMPAGE paging stations IN7 IN8 17 Input gain adjust GAIN IN7 IN8 18 Input micro line Euroblock connector MIC LINE IN7 IN8 19 RS 232 connector TP NET protocol 20 Input gain adjust GAIN IN5 IN6 21 Input micro line Euroblock connector MIC LINE IN5 IN6 22 Input gain adjust GAIN IN3 IN4 23 Input line RCA conne...

Page 25: ...8 FUNCTION DIAGRAM ...

Page 26: ...26 9 BLOCK DIAGRAM ...

Page 27: ...y output zone Frequency response 0dB 0 5dB 10Hz 20kHz Flatness better than 0 1dB THD Noise 1kHz 1Vrms 0 005 Output Noise floor FFT 20Hz 20kHz 110dB Interchannel crosstalk 20Hz 20kHz 90dB CMRR 20Hz 20kHz 60dB typical Processing Input Level x16 Volume From Off to 0 dB MUTE Yes Polarity Yes HPF inputs 5 8 50Hz to 150Hz 3dB Metering VuMeter post Fader Stereo On Off Input Noise Gate x4 Inputs Input 5 t...

Page 28: ... Label Users and Zone Volume control ON OFF Label and Style Source selection ON OFF Label and Allowed sources Equalizer ON OFF Label and Style Color Controls Text and Background Mechanical Dimensions WxHxD 482 6x88x210 mm 19x3 5x8 3 in Weight 3 7 kg 8 1 lb Supply Mains 90 240VCA 50 60Hz Power consumption 20W Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb Auto X Over CAT5 up to 100...

Page 29: ...to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler es www ecler com ...