13
The connection of a balanced mono audio signal to a REMOTE port on the
eMIMO1616 matrix is made in the following way:
Hot or direct signal
>
Terminal 8 on the RJ45 connector
Cold or inverted signal
>
Terminal 7 on the RJ45 connector
Earth
>
Terminal 6 on the RJ45 connector
In the event of using an eMCONTROL1 remote panel to control a zone of the
installation, the eMCONTROL1 panel itself has an internal connector to receive the
audio signal from an adjacent, complementary panel, such as the WPaMIX-T, on the
pair from the example below. This configuration type is ideal for remote control of
the zone and audio from the zone itself: a single CAT5 standard cable is connected
between the eMCONTROL1 panel and a REMOTE port on the eMIMO1616 unit, to
provide the DC power supply, transmit digital control data, and send remote audio
signals from a physical input on the eMCONTROL1 complementary panel to the
eMIMO1616 unit.
5.5. PAGER A, PAGER B connections and priority PAGER / DUCKER
modules
In the local inputs section on the rear panel there are 2 ports called PAGER A and
PAGER B, with audio inputs internally matching INPUT 7 and INPUT 8
(respectively).
eMIMO1616
REMOTE ports
RJ45 connector on
eMCONTROL1
CAT5
Pair of wall panels, on which eMCONTROL1 (right) receives the balanced
audio from its complementary panel, WpaMIX-T (left)