5 Installation
!
ATTENTION
— The device emits RF energy in the ISM (Industrial, Scientific, Medical) band. Make sure
that all medical devices used in proximity to this device meet appropriate susceptibility specifications for
this type of RF energy.
!
ATTENTION
— The device is recommended for use in industrial environments. It is mandatory to employ
a functional ground connection to comply with safety requirements.
!
ATTENTION
— The device is not supposed to be disassembled. Do not break the seal!
!
ATTENTION
— This device has been designed to operate with dipole antennas having a maximum gain
of 13 dBi. Antennas having a gain greater than that are strictly prohibited for use with this device. The
required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
than that permitted for successful communication.
5.1 General
TIP
— Please consider the general behavior and physics of the wireless channel when deploying devices.
Placement of devices may need to be adjusted during functional testing.
5.2 Mounting
Figure 5-I: Dimensions are in millimeters (mm)
Screw the antenna to the device’s SMA connector.
Note: antenna is excluded from diagram
5.2.1 DIN Rail Mounting
Figure 5-II: DIN rail mounting
1. Use the self-tapping screws provided
to attach the device to DIN rail. Place
the screws through the small DIN rail
adapter plates and screw into device
in their designated position.
2. Place the device now-fixed adapter
on the top edge of DIN rail.
3. Push the device downwards so it
snaps into place.
TIP
— To release device from DIN rail, push the device downwards while pulling outwards.