PE-280
OPERATION
X7502313601
19
© 3/2015 ECHO Inc.
Move stop switch button (A) forward away from the STOP
position.
2.
Purge Bulb
Pump purge bulb (C) until fuel is visible in the “Clear” fuel
return line.
3.
Recoil Starter
Lay the unit on a flat area and keep movable attachment parts
clear of all obstacles. Firmly grip throttle handle and throttle
trigger lockout with left hand. Rapidly pull recoil starter
handle/rope (D) until engine fires.
Note: If engine does not start after 5 pulls, use Cold Start
Procedure.
Stopping Engine
1.
Throttle
Release throttle trigger and allow engine to return to idle
before shutting off engine.
2.
Stop Switch
Move stop switch button (A) backward to STOP position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall
engine. Have your ECHO dealer repair stop switch before using unit again.
Edger Operation Techniques
Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause
unconsciousness, serious injury, or death. Exhaust can cause serious burns. ALWAYS position unit
so that exhaust is directed away from your face and body.
C
D
A