background image

4

INTERNATIONAL

 

SYMBOLS

Symbol

description/application

Symbol form/shape

Symbol

description/application

Symbol form/shape

Hot

Surface

Carburetor adjustment

- Idle speed

Carburetor adjustment

- High speed mixture

Symbol

description/application

Symbol form/shape

Symbol

description/application

Symbol form/shape

Read and understand

Operator's Manual.

Wear eyes, ears and

head protection

Emergency stop

Fuel and oil mixture

Finger Severing

Carburetor adjustment

- Low speed mixture

Safety/Alert

Wear hand

protection. Use

two handed.

DO NOT smoke

near fuel.

DO NOT allow

flames or sparks

near fuel.

Wear slip

resistant foot

wear.

Engine choke

control.

Ignition
ON/OFF

Primer bulb

S

AFETY

 I

NSTRUCTIONS

PERSONAL

 

CONDITION

 

AND

 

SAFETY

 

EQUIPMENT

WARNING  

  DANGER

Power Blower users risk injury to themselves and others if the power blower is used improperly and or safety
precautions are not followed.  Proper clothing and safety gear must be worn when operating a blower.

Physical Condition --

Your judgment and physical dexterity may not be good:

• if you are tired or sick,
• if you are taking medication,
• if you have taken alcohol or drugs.

Operate unit only if you are physically and mentally well.

Eye Protection --

Wear eye protection that meets ANSI Z87.1 or CE
requirements  whenever you operate the blower.

Hand Protection --

Wear no-slip, heavy duty work gloves to improve your
grip on the blower handle.  Gloves also reduce the
transmission of machine vibration to your hands.

Breathing Protection --

Wear a face mask to protect against dust.

Hearing Protection --

ECHO recommends wearing hearing protection whenever
unit is used.

Proper Clothing --

Wear snug fitting, durable clothing;
• Pants should have long legs, shirts with long sleeves.
• DO NOT WEAR SHORTS,
• DO NOT WEAR TIES, SCARVES, JEWELRY.
Wear sturdy work shoes with nonskid soles;
• DO NOT WEAR OPEN TOED SHOES,
• DO NOT OPERATE UNIT BAREFOOTED.
Keep long hair away from engine and blower intake. Retain
hair with cap or net.

Hot Humid Weather --

Heavy protective clothing can increase operator fatigue
which may lead to heat stroke. Schedule heavy work for
early morning or late afternoon hours when temperatures
are cooler.

Summary of Contents for PB-403

Page 1: ...MODELS PB 650 Serial Number 04001001 04002000 WARNING DANGER Readrulesforsafeoperationandallinstructionscarefully ECHOprovidesthis Operator sManualwhichmustbereadandunderstoodforproperandsafeoperatio...

Page 2: ......

Page 3: ...l find safety alerts and helpful information messages preceded by symbols or key words The following is an explanation of those symbols and key words and what they mean to you This symbol accompanied...

Page 4: ...l Condition Your judgment and physical dexterity may not be good if you are tired or sick if you are taking medication if you have taken alcohol or drugs Operate unit only if you are physically and me...

Page 5: ...me pain in those areas Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress Injury RSI AnextremeRSIconditionisCarpalTunnelSyndrome CTS which could occur whe...

Page 6: ...perations Use only during appropriate hours Never use a higher speed setting then necessary to perform a task The higher the engine speed the louder the blower noise Be a good neighbor AvoidHotSurface...

Page 7: ...hot glowing particles of carbon from leaving the muffler Keep exhaust area clear of flammable debris 3 RECOILSTARTERHANDLE Pullrecoilhandleslowlyuntilstarterengages thenquicklyandfirmly When engine s...

Page 8: ...b l a W m e t s y S n o i t i n g I e p y t n o i t i n g i e g r a h c s i d r o t i c a p a c o t e n g a M l e e h w y l F g u l P k r a p S n i 6 2 0 0 m m 5 6 0 p a G Y 8 R M P B K G N m e t s y...

Page 9: ...pipe B and tighten 4 Loosen wing nut E completely and expand open stick handle clamp F 5 Align notches G in handle clamp with pipe pegs H Stick handle should be angled away from operator 6 Slide stic...

Page 10: ...rious personal injury may result Use an approved fuel container DONOTsmokenearfuel DO NOT allow flames or sparks near fuel Fuel tanks cans may be under pressure Always loosen fuel caps slowly allowing...

Page 11: ...imerBulb Prime Pump primer bulb D until fuel is visible and flows freely in the clear fuel tank return line Pump bulb an additional 4 or 5 times 4 Pull recoil starter handle D until engine fires 5 or...

Page 12: ...and 6 carefully IMPORTANT To avoid engine damage due to over revving do not block blower pipe opening 1 Use only during appropriate hours 2 Allow the engine to warm up at a fast idle for a few minute...

Page 13: ...O H 6 S H T N O M 0 7 2 R O S R U O H Y L R A E Y s e r u d e c o r P e c n a n e t n i a M r e l a e D o h c E d e d n e m m o c e R t r o P t s u a h x E r e d n i l y C n o b r a c e D n a e l C t...

Page 14: ...element can be cleaned and reused be certain it still fits the cavity in the air cleaner cover is installed with the original side out FUEL FILTER Level1 Tools required Fuel line hook 203 254mm 8 10 i...

Page 15: ...f cooling passage blockages or cleaning of cooling fins is considered Normal Maintenance Any failure attributed to lack of maintenance is not warranted Cleaning Grill 1 Remove accumulated debris from...

Page 16: ...ked periodically 1 Remove spark plug and engine cover four screws 2 Remove spark arrestor cover A and spark arrestor screen B from muffler Replace screen if plugged with carbon deposits 3 Install spar...

Page 17: ...E Do not adjust carburetor unless necessary If you have difficultly see your ECHO dealer BeforeAdjustment Check that Air filter is clean and properly installed Spark arrestor screen is free of carbon...

Page 18: ...gap incorrect Covered with carbon Fouled with fuel Spark plug defective Adjust 0 65mm 0 026in Clean or replace Clean or replace Replace plug Engine does not crank Internal engine problem See your ECH...

Page 19: ...personal injury may result Long Term Storage Over 30 Days Do not store your unit for a prolonged period of time 30 days or longer without performing protective storage mainte nance which includes the...

Page 20: ...maintenance of this product you may call the ECHO ConsumerProductSupportDepartmentat1 800 673 1558from8 30am to 4 30 pm Central Standard Time Monday through Friday Before calling please know the model...

Page 21: ...SEMBLY INSTALL BLOWER PIPES STICK HANDLE PAGE 9 1 Assemble clamps A onto both ends of flexible pipe B 2 Assemble straight pipe with swivel C into flexible pipe B 3 Assemble flexible pipe B to elbow D...

Page 22: ...se choke COLD START position to stall engine Have your ECHO dealer repair stop switch before using blower again A ECHO CONSUMER PRODUCT SUPPORT If you require assistance or have questions concerning t...

Page 23: ...650 U S X750002810 X7501126600 PB 603 U S X750002230 X7501125300 PB 650 Can X750003020 X7501126900 Favor de notar este cambio Las abrazaderas que vienen con este modelo para el ensamble del tubo flexi...

Reviews: