11
P
OWER
B
LOWER
O
PERATOR
'
S
M
ANUAL
O
PERATION
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
• Rotate spring loaded throttle handle downward to a comfortable
operating position.
STARTING
COLD
ENGINE
1.
Move throttle lever (A) to START/IDLE DETENT position.
2.
Close Choke - Cold Start.
Move choke (B) up to "Cold Start" position.
3.
Primer Bulb -Prime.
Pump primer bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4.
Pull recoil starter handle (D) until engine fires (5 or 6 pulls).
5.
Move choke (B) to run position and if necessary, restart engine.
NOTE
If engine does not start after 5 pulls, use cold start procedures.
NOTE
Allow engine to warm up before use.
STARTING
WARM
ENGINE
1.
Move throttle lever (A) to start/idle detent position.
2.
Pull recoil starter handle (D) and engine should start. Do not use
choke (B).
NOTE
If engine does not start after 5 pulls, use cold start procedures.
A
B
C
D
Summary of Contents for PB-403