background image

30

PURCHASED REPAIR PARTS, SHORT BLOCKS AND ACCESSORIES

•  90-day residential, or non-income producing warranty

•  30-day commercial, institutional, agricultural, industrial, income producing, or rental application warranty  

ATTENTION TWO-STROKE ENGINE POWER PRODUCT OWNERS

This ECHO two-stroke engine power product is a quality-engineered unit which has been manufactured to exact tolerances to provide superior 

performance.  To help ensure the performance of the unit, it is required to use two-stroke oil which meets the ISO-L-EGD Standard per ISO/CD 

13738 and JASO M345/FC/FD Standards.

  ECHO Power Blend™ Two-Stroke Oil 

is a premium two-stroke oil specifically formulated to meet 

ISO-L-EGD (ISO/CD 13738) and JASO M345/FC/FD Standards.  The use of two-stroke oils designed for other applications, such as for outboard 

motors or lawnmowers can result in severe engine damage, and will void your two-stroke engine limited warranty. 

THIS WARRANTY DOES NOT COVER DAMAGE CAUSED BY:

• 

Lack of lubrication or engine failure, due to the use of two-stroke oils 

that do not meet the ISO-L-EGD (ISO/CD 13738) and JASO M345/

FC/FD Standards. Engine problems due to inadequate lubrication caused by failure to use an ISO-L-EGD compliant and JASO M345/FC/

FD registered oil, will void the two-stroke engine limited warranty.  

ECHO Power Blend™ Two-Stroke Oil

 meets the ISO-L-EGD and JASO 

M345/FC/FD  Standard. Emission related parts are covered for 5 years residential use or 2 years commercial use regardless of two-stroke 

oil used, per the statement listed in the EPA or California Emission Defect Warranty Explanation. 

• 

damage caused by use of gasohol, containing methanol (wood alcohol), or gasoline containing less than 89 octane

.  Only use gasoline which 

contains 

89 octane or higher

. Gasohol which contains a 

maximum

 10% ethanol (grain alcohol) or 15% MTBE (methyl/tertiary/butyl/ether) 

is also approved. The prescribed mixing ratio of gasoline to oil is listed on the ECHO oil label and covered in your operator’s manual.

• 

Engine damage caused by use of ether or any starting fluids.  

• 

damage caused by tampering with engine speed governor or emission components, or running engines above specified and recommended 

engine speeds as listed in your operator’s manual.

• 

Operation of the unit with improperly maintained/removed cutting shield or removed/damaged air filter.  

• 

damage caused by dirt, pressure or steam cleaning the unit, salt water, corrosion, rust, varnish, abrasives, and moisture.

• 

defects, malfunctions or failures resulting from abuse, misuse, neglect, modifications, alterations, normal wear, improper servicing, or use 

of unauthorized attachments. 

• 

Incorrect storage procedures, stale fuel, including failure to provide or perform required maintenance services as prescribed in the operator's 

manual.  Preventative maintenance as outlined in the operators manual is the customer’s responsibility.

• 

Failures due to improper set-up, pre-delivery service or repair service by anyone other than authorized ECHO servicing dealer during the 

warranty period.

• 

Certain 

parts and other items are not warranted, including but not limited to: lubricants, starter cords, and engine tune-ups. 

• 

use of spark plugs other than those meeting performance and durability requirements of the OEM spark plug listed in the Operator's 

Manuals.

• 

Overheating or carbon scoring failures due to restricted, clogged exhaust port or combustion chamber, including damage to spark arrester 

screen.

• 

Adjustments after the first (30) thirty days and beyond, such as carburetor adjustment and throttle cable adjustment. 

• 

damage to gears or gear cases caused by contaminated grease or oil, use of incorrect type or viscosity of lubricants, and/or failure to comply 

with recommended grease or oil change intervals.

• 

damage caused by loading SHREd 'N' VAC

®

 

 beyond recommended capacity. 

• 

damage caused by pump or sprayer running dry, pumping or spraying caustic or flammable materials, or lack of or broken strainers. 

• 

Additional damage to parts or components due to continued use after operational problem or failure occurs. Should operational problem or 

failure occur, the product should not be used, but delivered as is to an authorized ECHO servicing dealer.

It is a dealer’s and/or customer’s responsibility to complete and return the warranty registration card supplied with your ECHO product or by visiting 

WWW.ECHO-USA.COM

y

our receipt of purchase including date, model and serial number must be maintained and presented to an authorized 

ECHO servicing dealer for warranty service. Proof of purchase rests solely with the customer. Some states do not allow limitations on how long 

an implied warranty lasts, so the above limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so you may also have other specific legal rights which vary from state to state. This limited warranty is given by ECHO 

Incorporated, 400 Oakwood Rd., Lake Zurich, IL 60047.

DISCLAIMER OF IMPLIED WARRANTIES

This limited warranty is in lieu of all other expressed or implied warranties, including any warranty of FITNESS FOR A PARTICuLAR PuRPOSE 

OR USE and any implied warranty of 

MERCHANTABILITY

 otherwise applicable to this product. ECHO and its affiliated companies shall not be 

liable for any special incidental or consequential damage, including lost profits. There are no warranties extended other than as provided herein. 

This limited warranty may be modified only by ECHO.

99922201032

01/2010

Summary of Contents for HC-150 - 11-09 1

Page 1: ...MODEL HC 150 WARNING Read rules for safe operation and all instructions carefully ECHO provides this Operator s Manual and a Safety Manual Both must be read and under stood for proper and safe operati...

Page 2: ...ernational Symbols 3 Personal Condition and Safety Equipment 3 Equipment Check 6 Emission Control 8 Description 7 Contents 9 Assembly 9 Install Blade Stiffener 10 Remove Blade Stiffener 11 Operation 1...

Page 3: ...ts Wear hand protection Use two handed DO NOT smoke near fuel DO NOT allow flames or sparks near fuel Wear slip resistant foot wear Ignition Ignition ON OFF Do not operate with out guards in place Kee...

Page 4: ...ensa tions followed by loss of color and numbness in the fingers The following precautions are strongly recommended because the minimum exposure which might trigger the ailment is unknown Keep your bo...

Page 5: ...lieved that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those areas Certain repetitive hand activities m...

Page 6: ...ks are found Check that the cutting attachment is firmly attached and in safe operating condition WARNING Moving parts can amputate fingers or cause severe injuries Keep hands clothing and loose objec...

Page 7: ...hat you understand and follow the instruc tions on them If a decal cannot be read a new one can be ordered from your ECHO dealer See PARTS ORDERING instructions for specific information P N X505002310...

Page 8: ...IL STARTER HANDLE Pull handle slowly until recoil starter engages then quickly and firmly DO NOT pull rope all the way out or allow the handle to snap back damage to the starter will occur 9 FUEL TANK...

Page 9: ...ashers WARNING Hedge Clipper blades are very sharp Touching them may lead to severe personal injury Avoid touching blades whenever possible and always wear gloves to protect hands IMPORTANT Follow bla...

Page 10: ...Hold blade bolts from turning using a 10mm wrench Note Use new locknuts every time blade stiffener is installed IMPORTANT If blade stiffener is damaged or show signs of wear replace it Note Washers C...

Page 11: ...approved Two Stroke Oil A two stroke engine oil meeting ISO L EGD ISO CD 13738 and J A S O FC FD Standards must be used Echo brand premium Power Blend X TM Universal 2 Stroke Oil meets these standard...

Page 12: ...RTANT Stored fuel ages Do not mix more fuel than you expect to use in thirty 30 days ninety 90 days when a fuel stabilizer is added IMPORTANT Stored two stroke fuel may separate ALWAYS shake fuel con...

Page 13: ...le securely with one hand and pull the recoil starter handle D until engine fires or 5 pulls maximum 5 Choke After engine fires or 5 pulls move choke B to the RUN OPEN position Restart engine if neces...

Page 14: ...el is visible and flows freely in the clear fuel tank return line Pump bulb an additional 4 or 5 times 3 Recoil Starter Place the unit on a flat clear area Grip the front handle securely with one hand...

Page 15: ...your unit achieve that goal If you are unsure or are not equipped with the necessary tools you may want to take your unit to an ECHO Service Dealer for maintenance To help you decide whether you want...

Page 16: ...ws Nuts Bolts Inspect Tighten Replace 1 I All recommendations to replace are based on the finding of damage or wear during inspection 2 Inspect blade and clean and sharpen as needed Lubricate blades p...

Page 17: ...formed 4 If filter can be reused be certain it Fits tightly in the air filter cavity Is installed with the original side out 5 Install air filter cover NOTE Carburetor adjustment may be needed after a...

Page 18: ...quired 3 mm Hex wrench 25 or 50 mm 1 or 2 in clean ing brush Parts required None if you are careful IMPORTANT To maintain proper engine operating temperatures cooling air must pass freely through the...

Page 19: ...cover forward disengaging muffler gasket tabs and ignition lead and lay aside 6 Loosely install spark plug to keep debris out of the cylinder Use brush to remove dirt from cylinder fins IMPORTANT DO...

Page 20: ...nder 3 Remove exhaust guide A gasket B and screen C from muffler body 4 Clean carbon deposits from muffler components NOTE When cleaning carbon deposits be careful not to damage the cata lytic element...

Page 21: ...eposits from cylinder exhaust port IMPORTANT Never use a metal tool to scrape carbon from the exhaust port Do not scratch the cylinder or piston when cleaning the exhaust port Do not allow carbon part...

Page 22: ...mpliance above 1 100 feet ASL the carburetor may need to be ad justed by an authorized ECHO service dealer Important If the engine is adjusted for operation above 1 100 feet ASL the carburetor must be...

Page 23: ...ect hands 1 Move stop switch to stop position 2 Disconnect spark plug wire from spark plug 3 Brush loose debris from blade and coat both sides of blade with the 50 50 cleaning mixture 4 Allow cleaning...

Page 24: ...cess grease from around grease fitting 1 Move stop switch to stop position 2 Disconnect spark plug wire 3 Remove blade stiffener see Blade Stiffener Remove Install in structions 4 Slide blades to allo...

Page 25: ...t a safe distance from sharp blades IMPORTANT Blades should only be removed and reinstalled by an Authorized ECHO Servicing Dealer otherwise premature wear or internal damage may occur 1 Tighten blade...

Page 26: ...o h c E r u o y e e S r e l a e d o h c E r u o y e e S g u l p t a k r a p S k r a p s o N t c e r r o c n i p a g k r a p S n o b r a c h t i w d e r e v o C l e u f h t i w d e l u o F e v i t c e...

Page 27: ...oil dirt and debris from exterior of unit 4 Perform all periodic lubrication and services that are required 5 Apply clean oil to the entire length of the blade Be certain the blade bolts are lubricat...

Page 28: ...M345 FC FD two stroke air cooled engine oil Gasoline Use 89 Octane unleaded Do not use fuel containing methyl alcohol more than 10 ethyl alcohol or 15 MTBE Do not use alternative fuels such as E 15 or...

Page 29: ...NS For two stroke engine powered products the electronic ignition module flexible drive cables SRM solid drive shafts and TC tines are warranted for the life of the product on parts only Cutting attac...

Page 30: ...ge procedures stale fuel including failure to provide or perform required maintenance services as prescribed in the operator s manual Preventative maintenance as outlined in the operators manual is th...

Page 31: ...t SORE was designed built and equipped to conform with applicable EPA and C A R B emissions standards and that your equipment SORE is free from defects in material and workmanship that would cause it...

Page 32: ...ce repairs proof of purchase is required echo consumer product support If you require assistance or have questions concerning the applica tion operation or maintenance of this product you may call the...

Reviews: