STORAGE
Storage
PREPARATION FOR STORAGE
The following procedures should be followed prior to storage of your
generator for periods of 6 months or longer.
1. Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making
engine starting difficult. Add fuel stabilizer to fuel tank.
2. Remove the drain screw of the carburetor.
3. Change engine oil.
4. Check for loose bolts and screws, tighten them if necessary.
5. Clean generator thoroughly with clean cloth. NEVER USE WATER
TO CLEAN GENERATOR.
6. Pull recoil starter handle until resistance is felt, leaving handle in
that position.
7. Store generator in a well ventilated, low humidity area.
Generator Specifications
Engine Model
R420D-V
Start
Manual/Electric
Rated Frequency
60Hz
Rated Voltage
120V/240V
Rated Power
7.5KW
DC Output
12V, 8.3A
Fuel Tank Capacity
25L
Full Load Continuum Running Time
6h
50% Load Continuum Running Time
8h
Noise (7m)
84dB
Specifications for the Panel
2 x GFCI Duplex with water
proof cover, 1 x 120V- 30A
Twist lock-3prongs with
water proof cover, 1 x
120/240V- 30A Twist lock-4
prongs with water proof
cover, 3 in 1 digital meter,
Auto idle switch, Cigarette
lighter
Certification
CSA/EPA/CARB
LOW THD
Yes
Wheels & Kits
Yes