32
32
ERROR
CODES
ERROR
CODES
CAUSES
POSSIBLE
CAUSES
CORRECTIVE
MEASURES
ADDITIONAL
INFO
01H
LE1
Voltage of inverter
power is low.
Voltage of utility power
is too low.
Check if utility power
supply matches
voltage of inverter.
Inverter is broken.
Replace inverter.
Filter is broken.
Replace filter.
Choke is broken.
Replace choke.
Inspect whether
the utility power is
110/220V.
02H
NTCF
Temperature sensor of
inverter is abnormal.
Temperature
sensor of inverter
is broken.
Replace inverter.
04H
OC
Inverter outputs
overcurrent.
Running belt/deck is
aging.
Add lubricant to
running belt.
Running belt/deck is
broken.
Replace running belt
and deck.
Inverter is broken.
Replace inverter.
06H
OE
Inverter is overcurrent. Wire of brake
resistor is
disconnected.
Check wires.
Brake resistor is broken.
Replace brake resistor.
Inverter is broken.
Replace inverter.
07H
FOT
IGBT on inverter
is abnormal.
IGBT on inverter is
abnormal.
Replace inverter.