L
ON
W
ORKS
RTR-10 Module User’s Guide
4-3
Recommended PCB hole pattern (component side view)
for AMP part number 822021-1 (vertical mounting)
±.03 (x2)
±.03
8.26mm
1.27mm
6.35mm
35.56mm
35.56mm
2.54mm
2.54mm
1.27mm
2.41mm
1.63mm
1.02mm
(1.400)
(0.950 ±.001)
(0.640 ±.001)
(0.040 ±.003)
Pin 1
±.08 x40
(0.100)
(0.050)
(0.100)
(1.400)
(0.250)
(0.050)
(0.325)
8.26mm
(0.325)
40
2
39
Notes:
1. Dimensions in mm (inches)
2. Tolerances ± .13mm (0.005)
3. All socket dimensions are subject to change. Contact AMP for the most current information.
Figure 4.2
RTR-10 Vertical Socket Pad Layout
RTR-10 PCB footprint when using AMP part number 4-382483-0
(component side, horizontal mounting)
Notes:
1. Dimensions in mm (inches)
2. Tolerances ± .13mm (0.005)
3. Do not position components in the overhang region.
4. Allow 12.7mm (0.5) clearance above PCB over the entire footprint area. Additional clearance required
during assembly to insert the module.
5. Socket dimensions are subject to change. Contact AMP for the most current information.
74.93mm
67.31mm
15.42mm
Socket Outline
Module Overhang
4.32mm
(2.950)
(2.650)
(1.300)
(0.170)
(0.670)
1
27.94mm33.02mm
Figure 4.3
RTR-10 Right-Angle Socket Mechanical Footprint
Summary of Contents for LONWORKS