E E P R O M S E T T I N G S
Doors midway – DFCF/DFCR LED will be off. DFOF/DFOR LED will be off
DLM - Door Limit setup
This signal sets up the door limits inputs.
See also EEprom setting DLI, DFCF/DFCR, DFOF/DFOR.
DLM EEPROM Door limit mask.
Setting example:
DLM 00: 00000000 (Door open and close limits going to DFOF/DFOR, DFCF/DFCR
inputs which drop DOF/DOR and DCF/DCR relays).
DLM 01: 00000001 N/A
DLM 02: 00000010 (Door cam control) DC relay output used to control Cam operation.
Nb: 1 sec delay from DO picking up after DC has dropped. (to allow time for cam
to drop and locks to break, to avoid lock “snagging”).
See also Input - Output, DFCF/R.
DLM 03: 00000011 (As per setting “00” but DOF/DOR and DCF/DCR relays are held up)
DLM 04: 00000100 (As per setting “00” but DCF/DCR relay picks up whilst running).
DRV - Drive type setup
This sets the drive output type. Relay output configurations are changed to suit equipment installed.
Refer to operation section for motion outputs.
DRV…EEPROM…Drive control type.
00: 00000000 “Standard hyd. block valve. 3010EN”
01: 00000001 ”DA DynaHyd valve.”
02: 00000010 “Soft valve. 3010/2CH/S”
03: 00000011 “VF type 1; Keb VF drive, Zetadyn VF drive”
04: 00000100 “1,2 speed AC”
05: 00000101 “GMV 3010/S, Blain EV100”, Maxton, Bucher LRV, EECO
06: 00000110 “VF type 2”
07: 00000111 “VF type 3; ABB VF drive”
DT - Door Time Close setup
This setting allows the door fully open time NOT to be canceled when a car-call or door closed button
(DCBF/DCBR) is pressed.
Setting example:
DT 00: 00000000 (NOT ALLOW pressing a car-call or door close button to cancel door timing).
DT 01: 00000001 (ALLOW pressing a car-call or door close button to cancel door timing).
DTCF - Door Time Car call (Front doors) close setup
Sets the amount of time before the front doors close for a car call whilst on normal operation.
DTCF EEPROM Front doors time close. (VALUE)
Set value for front door close time.
The time is set in 100ms increments.
1e: 00011110 = 3000ms, “3 seconds”
32: 00110010 = 5000ms, “5 seconds”
90: 10010000 = 14400ms, “14.4 seconds”
(01 to FF valid values.)
DTCR - Door Time Car call (Rear doors) close setup
Sets the amount of time before the rear doors close for a car call whilst on normal operation.
DTCR EEPROM Rear door time close. (VALUE)
Set value for rear door close time.
The time is set in 100ms increments.
1e: 00011110 = 3000ms, “3 seconds”