17
NOTE: Before attempting to remove the cover, call technical
support found on page 1
e. A wire has become disconnected inside the unit during
shipping. Make sure the gas is OFF. The front cover is held by six
screws, four on top, two on bottom. The knobs pull off. All the
wiring is done with push together plastic connectors. They are all
visible without further dismantling of the unit. It should be obvious
when a wire has become disconnected.
f. It is possible that some debris or epoxy might have entered the
water regulator. Check to see if the filter screen on the water inlet
is clear of debris. You can also reverse the hookup by taking your
water source and hooking it up to the water
outlet
side and back
flushing the system.
g. Propane gas cylinders sometimes are contaminated with air,
especially new tanks upon their first filling. Cycle the unit on and
off by using the shower head switch several times (5) to purge the
air from the gas.
Should a unit fail to light or stay lit after 10 cycles, Call
technical support found on page 1
Units starts, then shuts off:
a. The unit requires a minimum of about 0.5 gallons per minute (2
liters) and a minimum of about 20 PSI / 1.38 bar* Note, water
pressure is at the lower end of operating parameters. You will
need a sustained water pressure of approximately 40-60 PSI / 2.7-
4.1 bar for adequate use if you are using a 12/18/120/240 volt
pump. See ADJUSTMENT in previous section above.
b. High wind
c. Out of, or low on gas. Propane gas cylinders sometimes are
contaminated with air, especially new tanks upon their first filling.
Cycle the unit on and off by using the shower head switch several
times (5) to purge the air from the gas.