AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
EL22-NG
SERIAL #
:
TYPE GAS:
NATURAL GAS
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Ampe
res
Maximum W
orking P
ressure:
Recovery
Ra�ng:
ANSI Z21.10.3-2014/CSA 4.3-2014
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use
gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mu
s
t be in
stalled in accordance
with lo
cal codes or
, in the ab
sence of local
c
odes, the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54
or the
CSA B149.1, Natural
Gas and Propane Installation Code
140,000
25,000
4” w.c
(1Kpa)
10.5'' w.c
(2.61Kpa)
3.05'' w.c
(0.76Kpa)
150 psi
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
2.24
Input (btu/hr)
Manifold pressure (in. w.c)
CAN 2.17 STANDARD
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
OUTDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combus�ble
materials. Clearance should be 1.75 � to the le� and right side of combus�ble materials, and
6.75 � to the front.
Open on three sides and an overhead clearance of 36”
Not recommended in excess of 2,000 �. above sea level.
Category III Water Heater
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
EL22-LP
SERIAL #
:
TYPE GAS:
LIQUID PROPANE
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Ampe
res
Maximum W
orking P
ressure:
Recovery
Ra�ng:
ANSI Z21.10.3-2014/CSA 4.3-2014
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use
gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mu
s
t be in
stalled in accordance
with lo
cal codes or
, in the ab
sence of local
c
odes, the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54
or the
CSA B149.1, Natural
Gas and Propane Installation Code
140,000
25,000
9'' w.c
(2.24 Kpa)
13'' w.c
(3.23Kpa)
4.93'' w.c
(1.22Kpa)
150 psi
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
OUTDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combus�ble
materials. Clearance should be 1.75 � to the le� and right side of combus�ble materials, and
6.75 � to the front.
Open on three sides and an overhead clearance of 36”
CAN 2.17 STANDARD
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
Category III Water Heater
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
EL22-ING
140,000
SERIAL #
:
25,000
TYPE GAS:
NATURAL GAS
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
4” w.c
(1Kpa)
Volta
g
e:
120 Volts
Maximum Inlet Gas Pressure:
10.5'' w.c
(2.61Kpa)
Frequency:
60 Hz
Manifold Pressure:
3.05'' w.c
(0.76Kpa)
Amps:
Less than 12 Ampe
res
Maximum W
orking P
ressure:
150 psi
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
ANSI Z21.10.3-2014/CSA 4.3-2014
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
FOR YOUR SAFETY
Do not store or use
gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mu
s
t be in
stalled in accor
dance with
local codes or
, in the ab
sence of local c
odes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54
or the
CSA B149.1, Natural Gas and Propane Installation Code
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
2.24
Input (btu/hr)
Manifold pressure (in. w.c)
CAN 2.17 STANDARD
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 6 inches sides, 0 inches back and 12 inches top.
Not recommended in excess of 2,000 �. above sea level.
Category III Water Heater
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
EL22-ILP
140,000
SERIAL #
:
25,000
TYPE GAS:
LIQUID PROPANE
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
9'' w.c
(2.24 Kpa)
Volta
g
e:
120 Volts
Maximum Inlet Gas Pressure:
13'' w.c
(3.23Kpa)
Frequency:
60 Hz
Manifold Pressure:
4.93'' w.c
(1.22Kpa)
Amps:
Less than 12 Ampe
res
Maximum W
orking P
ressure:
150 psi
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
ANSI Z21.10.3-2014/CSA 4.3-2014
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CAN 2.17 STANDARD
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
Category III Water Heater
FOR YOUR SAFETY
Do not store or use
gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mu
s
t be in
stalled in accor
dance with
local codes or
, in the ab
sence of local c
odes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54
or the
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 6 inches sides, 0 inches back and 12 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.