materials. A minimum clearance of 6”(15.2cm) between the vent pipe and ceiling should be maintained.
Follow local codes.
For maintenance and inspection purposes, the
following holes are required to be made:
• Two (2) inspection openings that allow access to
venting. One (1) of these openings should be close
to where the vent pipe enters the ceiling. The other
opening should be near the vent termination.
• A ventilation hole with a 16 sq. in.(103cm
²
) opening
should be made at least every 10 ft.(3m).
NOTICE
:
Vent pipes must be completely insulated
closets, and garages and must not touch any
The water heater must be vented to the outdoors. Termination must be 50 cm away from any
obstructions and the termination must be at least 5 cm away from the wall, as described in these
or ducts with internal plastic coatings.) It is recommended to use included venting. Refer to your local
municipality if additional venting is needed.
The included vent termination should be used. If not, a termination hood with a screen must be used.
(Refer to page 19). Do not remove the terminal guard. The terminal outlet must not be covered by
anything.
Use a vent pipe with an antidisconnection
structure. The use of a High Temperature
Silicone (500° F, 260°C) may be required to seal
vent connections. To prevent accidental gas
another bead against the joint side of the stop
bead.
Follow vent manufacturer’s installation instructions. The water heater can be vented either horizontally
or vertically.
Vent pipe runs must be adequately supported along both horizontal and vertical runs.
WARNING: Refer to pages 9-11 for clearances from combustible materials.
Venting
IN
ST
A
LL
AT
IO
N
*Use Proper Support Straps
NO
YES
DANGER: Failure to install the vent adapter and properly vent the water heater to the outdoors as
outlined in the Venting section of this manual will result in unsafe operation of the water heater causing
proper operation as outlined in the Venting section of this manual.
(15.2cm)
(61cm)
(.6 cm)
(.3m)
(25 cm)
(25 cm)
10"
10"
Typical Horizontal Termination
w/ 1/4"(.6cm) per foot(.3m)
UPWARD Slope