14
|
P a g e
E580 Defra instructions manual |
current as of May 2015
All information supplied by
Ecco Stove
TM
is a trade mark of Landy Vent UK Limited
copyright©EccoStove2015
Ecco Stove
| Foster House
| 2 Redditch Road,
Studley,
B80 7AX, United Kingdom
T
| +44 (0)1527 857 814
E
W
| www.eccostove.com
Patent pending USA, Canada, Europe & Russia | UK Patent nos: 2467433 & 2498883
Tar deposits will not form if seasoned logs of 20-25% moisture are burned at 160°C or above
(recorded on the top plate) within your Ecco Stove. If tar deposits form within the stoves
flue ways or fire box it is clear indication of poor quality unseasoned wood being burned.
Damage will occur within your stove along with poor performance.
18.
FLUE CONNECTION AND FLUE LININGS
Under no circumstances should the diameter of any flue or lining leaving the stove be
reduced less than its 150mm diameter flue outlet.
The stoves connector pipe must have an access panel/soot door built in within 200mm of
the stoves top for cleaning within the stove’s internal flue ways and for stove pipe lining
sweeping.
The flue lining and flue ways in the stoves top must be cleaned a minimum of twice every
seasons burning.
Any joints between pipes and linings should be self tapped together.
6” linings are suitable for flue heights up to 9 metres
7” linings should be used above 9 metres in height.
High temperature hot face linings are suitable but not above 225 x 225 in section.
It is advisable not to connect the Ecco Stove E580 to clay linings within chimneys, unless
those clay linings have a hot face liner fitted within, in order to reduce condensation within
the chimney flue.
ANY FLUE INTENDED FOR USE MUST BE SWEPT IN ADVANCE AND TESTED FOR SUITABILITY
PRIOR TO THE APPLIANCE BEING INSTALLED. IF INSTALLINGTHIS STOVE ONTO AN
EXISTING FLUE WHICH IS DEEMED/TESTED AS SUITABLE WHICH WAS PREVIOUSLY USED
FOR AN OPEN FIRE, THE FLUE MUST BE SWEPT AGAIN WITHIN A MONTH OF INSTALLATION
AS THE HIGHER TEMPERATURE OF FLUE GASES MAY LOOSEN THE OLD OPEN FIRES BUILT
UP DEPOSITS, TO ENSURE BLOCKAGE DOESN’T OCCUR.
19.
CLEANING AND MAINTENANCE
The Ecco Stove E580 under top flue way must be cleaned at least twice in a burning season.
Access must be left in the stoves pipe within 200mm of the stoves top and brushed forward
into the stove under top flue way from there.
a)
SEASONAL USE
b)
Repairs or replacements must be carried out by a competent engineer.
c)
Ensure the flue way accessed through the stove pipes cleaning door (within 200mm of
the stoves top) is brushed or vacuumed out