background image

 

1

0

4

0

2

0

4

0

0

5

0

 
 

 
9.

 

In program mode you can lock and unlock the system as follows:  

 

To LOCK the system                                                                 =>

 one long Beep 

to confirm.  

 
To UNLOCK the system                                                           => 

one long Beep 

to confirm.

 

 

 
In LOCK mode, the system will not function or make any calls or activate the output.  
In lock mode the system will announce “wrong command” for any attempt to make a call or activate 
the output relay by the key pad.      

 

10.

 

In program mode you can activate the output relay (according to the Function chosen) by the 
following command:   

 

 

 

11.

 

In program mode you can program to limit the “ talking time “ of the visitor as follows:  

 
 

 

 

The letter “ T ” represents the Time chosen (in minuets) and it can be between 1 to 9 minutes.    

 

The deflate setting of “Talking Time” Must be 1 minute.  

 

The system must end up each call (after the chosen “Talking Time” ) by a long BEEP. 

 

In future productions the system must end up each call by an announcement:  

       “ END OF CALL” . 

 
 
 
 

All Rights Reserved to  

ECA  

Electronic Engineering Pty. LTD. 

AUSTRALIA

 

Tel: +61 3 95720535

 

[email protected]

 

www.gatesonsolar.com

 

   

 

T

0

6

0

Summary of Contents for MCI-3000V1

Page 1: ...rding to the manual General information On standby when the key is pressed the system will announce Please press the unit number followed by the key After which the visitor will press 1 for house number one or 23 for house number twenty three etc etc Then the system will dial the first number of the house unit which was entered for the number of rings as was programmed in the system If there was n...

Page 2: ... Program the Master Phone Number Press 0 0 0 enter master phone number Then you will hear the announcement The number is Note The system will always answer the call made by the MASTER phone number and then enter Program Mode automatically to allow the master to do all the programming wirelessly using his phone s keypad 2 Programming the users phone numbers The following letters and configuration r...

Page 3: ... The phone number was deleted 3 Deleting the user s phone number There are three ways to delete the user s phone number form the system 1 by entering a new phone number into the same memory location of the user 2 by clearing deleting the memory location of the user 3 by using the user s phone number to delete it from the system 4 or by deleting all the phone numbers in the system 1 To delete a use...

Page 4: ...ber The Pin Code is The following examples show programming the pin code 9572 for user No 1 in unit 1 and the pin code 5552 for user No 2 in unit 22 The system will announce the new pin code The pin code is 2 How to DELETE the pin code of a certain specific user There are three ways to delete the user s pin code from the system I By entering a new pin code for the same user II By deleting the pin ...

Page 5: ...n is MOMENTARY pulse of 3 seconds The pulse time of the relay can be set from second to 10 seconds as follows Enter 0 0 1 0 for second pulse time Enter 0 0 1 1 for 1 second pulse time Enter 0 0 1 2 for 2 second pulse time Enter the Time required here Enter 0 0 1 8 for 10 second pulse time Enter 0 0 1 9 for 15 second pulse time The system will confirm the set time by a Beep sound as long as the cho...

Page 6: ...activate the output relay according to the Function chosen by the following command 11 In program mode you can program to limit the talking time of the visitor as follows The letter T represents the Time chosen in minuets and it can be between 1 to 9 minutes The deflate setting of Talking Time Must be 1 minute The system must end up each call after the chosen Talking Time by a long BEEP In future ...