background image

 

Choosing Single or Double swing gates in the control panel 

 

This control panel can be used for one single swing gate as well as for double swing gates.  
In order to select and change the operation to be for a single gate, do as follows:  

1.

 

Remove the Jumper “FUNCTION” in the control panel.  

2.

 

Press and release button ( I ) on the remote control and the light relay will “Click” once.   

3.

 

Return the Jumper into its place. End.  

4.

 

For changing the setting back to dabble swing gate operation repeat step 1 to 3 and the 
control panel will confirm that by two “Click” sounds in the light relay.      

 

 

How to Cancel the opening time delay between the gates 

 

The control panel sets two seconds 

opening time delay

 between the Master (M1) and the Slave gate 

(M2) automatically. However, you can cancel this “opening time-delay” so that both the gates will open 
and close simultaneously. For selecting 

with or without

 

“opening time delay” 

do as follows

1.

 

Remove the jumper “TIMER”  

2.

 

Press and release the button ( III ) on the remote control. A double “click” by the light relay will 
confirm cancellation of the time delay, i.e. both gates will always open and close simultaneously.  

3.

 

Put Jumper Timer back into its place.   

4.

 

To change back the setting to be with two seconds time delay; repeat the above procedure and this 
time three “click” sounds will be heard to confirm and indicate this selection. 

 

 

Setting the opening and closing TIMERS and the delay TIME between the gates    

 

There are 5 timers in the control panel that need to be set according to the working time of each 
motor. For each motor there are two timers that are needed to be set. The first timer called (T1) is 
to be set for the period of time you would like Motor-1 to go fast, and the second timer (T2) is the 
period of time you would like Motor-2 to go slow. 
The third timer (T3) is to be set for the period of time you would like Motor-2 to go fast, and the 
forth timer (T4) is the period of time you would like Motor-2 to go slow. 
In addition to the above four timers, there is another timer (T5) which is for setting the 

time delay

 

between the two gates while they close. Motor-2 (gate No. 2) closes first and after a few seconds 
(set by timer T5) Motor-1 (gate NO. 1) will close behind it. See diagram as followed.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

T

1

T

2

T

3

T

4

T

5

M o to r  1

M o to r  2

S e ttin g  tim e r s  fo r  o p e n in g

S e ttin g  tim e  d e la y  fo r  c lo s u r e

F

A

S

T

F

A

S

T

S L O W

S L O W

M o to r  2

M o to r  1

M o to r-2  w ill c lo s e  firs t,

a n d  a fte r a  p re s e t tim e  o f tim e r T

5

M o to r-1  w ill c lo s e  s e c o n d .

Reviews: