background image

 

HOW TO ACTIVATE THE LOCK REALESE FUNCTION         

   

   

  

1.

 

Remove Jumper “FUNCTION” in the CP. 

2.

 

Press and release button ( III )on the remote control.  

3.

 

Return Jumper into its place. END.    

4.

 

To restore, repeat step 1 to 3

 and two “Click” sounds will confirm your selection. 

 

 

HOW TO CANCEL THE SLOW DOWN SPEED AT THE END OF OPENING AND CLOSING       

   

   

  

1.

 

Remove Jumper “FUNCTION” in the CP. 

2.

 

Press and release button ( II )on the remote control.  

3.

 

Return Jumper into its place.  

4.

 

To restore the slow down feature repeat step 1 to 3

 and two “Click” sounds will confirm your selection. 

 

 

HOW TO ACTIVATE THE PHOTO SENSOR IN OPENING CYCLE        

   

   

  

The photo sensor is active only during closure mode for safe closure. However, you can choose 
to activate the photo sensor to be activated during opening mode as well in order to prevent the 
gates  from  starting  to  open  in  case  any  car  is  standing  too  close  to  the  gates.  To  activate  the 
photo sensor for opening mode do as follows:   

 

1.

 

Remove the jumper “TIMER”  

2.

 

Press and release the button ( IV ) on the remote control. 

3.

 

Return the Jumper to its place.   

 

Control Panel DCP-242V2 

Summary of Programmable Features  

Functionality of Jumpers;  

“REMOTE”    :   For teaching or deleting remote controls.  
“PROGRAM”:   For choosing 

Automatic

 or 

Set By Step

 mode. 

“ POWER”     :   For adjusting the force of the motors.   
“FUNCTION”:   For selecting; Single/Double gate, with/without Lock Release, Lock/Light relay          
 “TIMER”        :  For setting 

Fast 

and 

Slow

 time, 

Time delay

 in Auto-Close, with/without opening delay,  

                             and for selecting type of invertors.   

 

REMOTE 

CONTROL’S 

BUTTON

 

Jumper  

FUNCTION 

 

Double / Single Gate   

II 

With / Without Ramp Down 

III 

With / Without Lock Release 

 

IV 

Light / lock relay  

 

REMOTE 

CONTROL’S 

BUTTON

 

Jumper  

TIMER  

Setting Fast and Slow time 

II 

Setting Auto Close Time Delay  

III 

With/Without opening delay  

IV 

W/WO PE sensor in opening    

 

Manufactured by:  

ECA Electronic Engineering Pty. Ltd. Australia.   

465 Hawthorn Rd. Sth. Caulfield 3162 Vic.  Tel:03-95720535     Fax:03-95720536  

[email protected]

   

www.gatesonsolar.com

   

    

                                  

REMOTE 

CONTROL’S 

BUTTON

 

Jumper  

PROGRAM 

 

Step By Step program (o/s/c) 

II 

Automatic closure program   

III 

IV 

REMOTE 

CONTROL’S 

BUTTON

 

Jumper  

POWER  

 

Max. Power  

II 

Min. Power  

III 

To Increase power by one level  

IV 

To Reduce power by one level 

Reviews: