14
K000104 - BW4+
EN
3. A S S E M B LY
Suitable protective clothing i.e. goggles, gloves and shoes shall be worn
during installing and/or maintenance of plate heat exchangers. Please
be aware of:
■
filled plate heat exchangers might be heavy,
■
plate heat exchangers can be hot from high temperature operation,
■
condensate might be corrosive/caustic.
Please follow the steps in this instruction. This will make your work easier
and ensure a high quality conversion.
3.3
L I P S E A L
■
Remove the lip seal in the exhaust outlet of the power unit with a slotted screw-
driver and replace it with the
lip seal D60 (5)
supplied.
3.2
M O U N T I N G B R A C K E T
■
Place the
mounting bracket (1)
on the exhaust outlet of the Power Unit and fix
the mounting bracket with
8 x bolts M4x10 (2)
and
2 x washer M4 (3)
using a
3
mm Allen screwdriver i
n the existing holes.
■
Drill 8 holes into the Power Unit rear panel through the existing 8 holes of the
mounting bracket using a power drill with a
4mm
metal drill
.
■
Attach the mounting bracket with
8 x blind rivets (4)
using a blind rivet gun.
Caution when drilling to prevent damage to components inside the Power
Unit.
Max. drilling hole depth: 2 cm
3.1
G A S H O S E C O N N E C T I O N
■
Wrap
sealing tape
around the
angle (8)
.
■
Screw the
angle (8)
into the gas hose connection on the Power Unit.