Chengdu Ebyte Electronic Technology Co.,Ltd.
NA611-S & NA611-SA User Manual
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
第
7
页
understanding of the host computer. The host computer uses AT to quickly interact with the device. Users can
configure the device directly through AT, and the effect is the same as that of the host computer. machine is
consistent.
Basic Information Area------Product Parameters
Version information/MAC address are inherent parameters of the device, users can only read
The local IP is a parameter that will be valid only for the query after the device is connected to wifi, reflecting
the ip of the device itself.
Idle restart If it is checked, it means idle restart is enabled. If the device does not perform any network
information interaction and 485 information interaction within the idle restart time, the software will restart the
device. Idle restart time in minutes.
Network AT header configuration The default network AT header of the device is NETEbyte, that is to say, the
data sent on the network, if it has this header, it will be regarded as an AT command and will not be regarded as
information. This header can be configured by the user. Yes, not Chinese, and the length is between 3-23 English
characters and numbers. For example, after setting up network communication, send NETVER\r\n The
device will reply to your relevant device information through the network (\r\n is carriage return, line feed, not
string), for more AT commands, see the device's AT manual.
Basic information area------ serial port parameters (configured to take effect after restarting)
Multilink Protocol Distribution Mode If checked, for example, you have created two links to connect to two
TCPS servers respectively, then the information sent by the TCPS server will be sent out through 485 with a
specific header, the header length is 5 bits, and the distance For the content of the header, check the content of the
following protocol transmission. At the same time, whether you check this option or not, send information to 485
and upload it to the network. The information can have a header, such as the header designation is to link 1. If it is