Chengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012-2023, Chengdu Ebyte Electronic Technology Co., Ltd
15
Send: C1 00 04
Return: C1 00 04 12 34 00 61
3
formatting
error
Format Error Response
FF FF FF FF
8.2 Register Description
address
fill out or in
(informatio
n on a form)
name (of
a thing)
descriptive
note
00H
Read/Write
ADDH
ADDH (default 0)
Module address high byte and low
byte. Note: When the module address is
equal to FFFF, it can be used as the
broadcast and listen address, i.e.: at this
point the module will not be address
filtered1
01H
Read/Write
ADDL
ADDL (default 0)
02H
Read/Write
NETID
NETID (default 0)
Network address for distinguishing
networks. It should be set to the same
when communicating with each other.
03H
Read/Write
REG0
7 6
5
UART serial port rate
(bps)
Two modules communicating
with each other can have different
serial port baud rates. The checksum
method can also be different.
When
transmitting
larger
packets continuously, users need to
consider the data blocking and even
possible loss caused by the same
baud
rate.
It
is
generally
recommended that both sides of the
communication have the same baud
rate.
0 0
0
Serial port baud rate of
1200
0 0
1
Serial port baud rate of
2400
0 1
0
Serial port baud rate of
4800
0 1
1
Serial port baud rate of
9600 (default)
1 0
0
Serial port baud rate of
19200
1 0
1
Serial port baud rate of
38400
1 1
0
Serial port baud rate of
Summary of Contents for E90-DTU(400SL47)