Example
:
AT+UPCFG=0
14
AT+PWCFG
Setting /Querying the power parameter(reboot valid)
AT+PWCFG=?
Description
:
Gets the power parameter
Response
:
PWCFG:3
AT+PWCFG=Value
Description
:
Value:0~3
0
:
Polar Altitude
1
:
High
2
:
Medium
3
:
Low
Example
:
AT+ PWCFG=3
15
AT+IOCFG
Setting /Querying the IO parameter
AT+IOCFG=?
Description
:
Gets the IO parameter
Response
:
IOCFG:0
AT+IOCFG=Value
Description
:
Value
:
0 or 1
0
:
Push-pull
1
:
open-drain
Example
:
AT+IOCFG=0
16
AT+DFCFG
Restore the default parameter
AT+DFCFG
Description
:
Null
Restore the default parameter
Example
:
AT+DFCFG
17
AT+RSTART
Device Restart
AT+RSTART
Description
:
Null
Device Restart
Example
:
AT+RSTART
18
AT+ECHO
Sets up the AT instruction to turn off the back display
AT+ECHO=Value
Description:
Value:0 or 1
1
:
Close the echo
0
: