Wireless UART Module User Manual of E64 Series Modules
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
5
/
16
1.
Features
l
Star network:
It supports a maximum of 31 slaves to send data to master at the same time. Eight groups with 31 slaves of network
can run simultaneously in the same area.
l
Handshake:
The handshake between the master and the slave will make the whole communication more reliable. Once one of the
transceivers starts a communication and the communication is being interfered, the transmitter will retransmit the data for a
maximum of three times. The users can receive the transmitting results.
l
Ultra-low power consumption:
WOR (wake on radio),is especially suitable for battery powered applications. When module
works at slave-receiver mode (mode 2), the module’s maximum receiving response time is 2000ms, and the average current is
below 30uA.
l
FEC:
Forward Error Correction has high coding efficiency & good correction performance. In case of sudden interference, it can
correct the interfered data packets proactively, so that the reliability & transmission range are improved correspondingly. Without
FEC, those data packets can only be dropped.
l
Encryption Algorithm:
The module has the function of data encryption & compression. The data transmitted features
randomness. With such function, data interception becomes pointless. Data compression can decrease the transmission time &
probability of being interfered, while improving the reliability & transmission efficiency.
l
Watchdog:
With a built-in watchdog, the module runs precise layout and time. Once an exception occurs, the module will restart
in 0.107 second, and continue to work according to the previous parameters.
l
Sleep
mode:
When the module works in sleep mode (Mode 3), it is available for configuration, but not for transmitting & receiving.
The typical current is 2uA in this mode. It can still receive the configuration from the MCU.
2.
Technical Parameters
Model
Size
Net weight
Operating
temperature
Operating
humidity
Storage
temperature
E64-T100S2
17*30 mm
2.4±0.1g
-40 ~ 85℃
10% ~ 90%
-40 ~ 125°C
2.1 Electrical Parameters
2.1.1 E64-T100S2
Parameter
Min
Typ
Max
Unit
Transmitting current
84
89
98
mA
Receiving current
15
16
18
mA
Turn-off current
3
4
5
μA
Transmitting power
19
20
21
dBm
Receiving sensitivity
-119
-121
-123
dBm
Recommended frequency
425
433
451.3
MHz
Voltage supply
2.3
3.3
5.2
V
Communication level
2.5
3.3
3.6
V