Wireless UART Module User Manual of E64 Series Modules
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
13
/
16
-------------------------------------------------
--------------------------------------------------------
5
OPTION
2, FEC switch
0:Turn off FEC
1:Turn on FEC(default)
-------------------------------------------------
1, 0 transmission power (approximation)
00: 20dBm(default)
01: 17dBm
10: 14dBm
11: 11dBm
l
After turn off FEC, the actual data transmission
rate increases while anti-interference ability
decreases. Also the transmission distance is
relatively short.
l
Both communication parties must keep on the
same pages about turn-on or turn-off FEC.
--------------------------------------------------------
l
The external power must make sure the ability
of current output more than 200mA and
ensure the power supply ripple within 100mV.
l
Low power transmission is not recommended
due to its low power supply efficiency.
For example: The meaning of No.3 “SPED” byte:
The binary bit of the byte
7
6
5
4
3
2
1
0
The specific value
(configurable)
0
0
0
1
1
0
0
1
Meaning
UART parity bit 8N1
UART baud rate is 9600
Air date rate is 2k
Corresponding hexadecimal
1
9
8.
Parameter Setting
When the module is in Mode 3 (M0=1 M1=1), the parameter can be set by instruction or software in PC.
Please visit
www.cdebyte.com to download the software.