For example, if the network ID entered at transmitter A is 02 and the network ID entered at receiver B is 10, then when
setting the module address at relay R, the hexadecimal value 0X020A is converted to the decimal value 522 as the
module address to be filled in by relay R.
That is, the module address to be filled in by relay R at this time is 522.
10. Firmware upgrades
The E610 module supports serial firmware upgrade, when special after-sales support is required, you can contact us for
the corresponding firmware for upgrade processing.
Upgrade method 1: Use the TTL to USB tool to connect the module VCC/TX/RX/GND and control the M0/M1 level to
enter the configuration mode. Select the firmware upgrade tab in the official configuration tool, click the "Open File"
button to select the firmware, then click Start Download and wait for the progress bar to reach 100%.
Upgrade method 2: Power down the module first, short the module AUX pin and GND pin and then power up (maintain
the short connection for at least 1 second and then release it), the module will automatically enter the upgrade mode, then
use the configuration tool to download the firmware.
11. Hardware Design
recommends the use of a DC regulated power supply to power the module with as low a ripple coefficient as
possible and the module needs to be reliably earthed.
Please take care that the positive and negative terminals of the power supply are correctly connected, as
reversing them may result in permanent damage to the module.