9. Uplink configuration instructions
The following figure shows the E610-433T20S configuration upper computer display interface, the user can switch
to command mode through M0, M1, in the upper computer for quick configuration and reading of parameters.
in the configuration of the upper computer, the module address, frequency channel, network ID, key are decimal
display mode; where the value range of each parameter.
Network address: 0 to 65535
Frequency channel: 0 to 83
Network ID: 0 to 255
Key: 0 to 65535
users need to pay special attention when using the upper computer to configure the relay mode, because in the upper
computer, the parameters are displayed in decimal mode, so the module address and network ID need to be filled in
by converting the decimal.