6.2 Normal mode

Mode 0

 

Type

 

When M0  = 0

M1  = 0

the module  works on  Mode  0

 

Transmitting 

The module  receives  the users’ data of serial  port, and transmit 58 bytes wireless data packet. When the 

input data packet reaches 58 bytes, the module will start the wireless transmission, thus users can continue 
to input the transmitting data; When the input data p acket is less than 58 bytes, the module will wait 3 by tes 
time, if there’s no more data packet input, it means the data input finished, so the module will send all data 
packet out via wireless; After the module receives  the first data packet, the AUX outputs low level; When 
module  put all data into RF chip and start the transmission, the AUX outputs high level;  At this time, it 

means the last data packet starts wireless transmission, users can continue to input 512 bytes data at most; 
The data packet sent in Mode 0 can be only received  by the module with Mode 0 and Mode 1. 

Receiving 

The module  always open the wireless receiving  function on, then it can  receive  the data packet sent by 
Mode 0 and Mode 1. 
After receiving  the data packet, the AUX of module  outputs low level and after delaying 5ms, the wireless 

data will be transmitted via TXD pins of serial port. After all wireless data is transmitted via serial port, the 
AUX outputs high level. 

6.3 WOR mode

Mode 1

   

Type 

When M0 = 1

M1  = 0

the module  works on Mode 1 

Transmitting 

The condition of module  starting data packet transmission and  the AUX function equal  to Mode 0. The 
only difference  is that module will add wake-up code automatically before each data packet. The length of 
wake-up code depends on the wake-up time set by users, the purpose of wake-up code is to wake up the 
module with Mode 2; So, the transmitting data in Mode 1 can be received by the module  with Mode 0, 1, 

2. 

Receiving 

It equals to Mode 0. 

6.4 Power saving mode

Mode  2

   

Type 

When M0 = 0

M1  = 1

the module  works on Mode 2 

Transmitting 

The module is on sleep mode, serial port is close, so it cannot receive  the serial port data of external M CU. 

Thus, this module does not feature wireless transmitting function. 

Receiving 

In mode 2, the transmitter must be work in Mode 1; Monitoring the wake-up code at regular  time, once a 
valid wake-up code is received, the module continue to receive  and wait for the entire valid data packet t o 
be  received;  Then AUX outputs low level,  after delaying  5ms, the serial  port is open and  the received 
wireless data will be transmitted via TXD, after that, AUX outputs high level;  Wireless module continue 

to enter  “Sleep-Monitor”working mode(polling);  Set  different  wake-up time,  the module  has different 
receiving  response time  (max  2s) and different  average  power consumption(min 30uA);  Users need  to 
strike a balance  between communication latency and average  power consumption. 

 

6.5 Sleep mode

Mode  3

 

Type 

When M0 = 1

M1  = 1

the module  works on Mode 3 

Transmitting 

Transmitting the wireless data is unavailable. 

Receiving 

Receiving  the wireless data is unavailable. 

Summary of Contents for E31-433T30D

Page 1: ...E31 433T30D User Manual AX5243 433MHz 1W DIP Wireless Module...

Page 2: ...ROADCASTINGTRANSMISSION 7 5 3 BROADCASTINGADDRESS 7 5 4 MONITOR ADDRESS 8 5 5 RESET 8 5 6 AUX DESCRIPTION 8 5 6 1 Indication of UART output 8 5 6 2 Indication of wireless transmitting 8 5 6 3 Configur...

Page 3: ...ology Co Ltd 2 8 HARDWARE DESIGN 15 9 FAQ 16 9 1 TRANSMISSION DISTANCE IS NOT IDEAL 16 9 2 MODULE IS EASY TO DAMAGE 16 9 3 BIT ERROR RATE ISTOO HIGH 16 10 WELDING OPERATION GUIDANCE 16 11 E31 SERIES 1...

Page 4: ...s the probability of reducing the transmission time reducing the probability of interference improving reliability and transmission efficiency E31 433T30D strictly abides by FCC CE CCC and other domes...

Page 5: ...5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial design Working frequency MHz 425 450 5 Support ISM band Power consumption Transmit current mA 680 Instant power consump...

Page 6: ...be grounded 3 RXD Input TTLUART inputs connects to external MCU PC TXD output pin Can be configured as open drain or pull up input 4 TXD Output TTLUART outputs connects to external RXD MCU PC input pi...

Page 7: ...2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 6 11 Fixed orifice Fixed orifice 4 Connect to MCU No Description STM8L MCU 1 The UART module is TTLlevel pls connect to theMCU of TTL 2 For some MC...

Page 8: ...r Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 5 Function description 5 1 Fixed transmission 5 2 Broadcasting transmission 5 3 Broadcasting address For example Set the addre...

Page 9: ...f check and sets the operating mode based on user s parameters During the process the AUX remains low level After the process completed the AUX outputs high level and starts to work as per the operati...

Page 10: ...of module Only happened when Reset and exit sleep mode 5 6 4 Notes for AUX For function 1 function 2 mentioned above the priority should be given to the one with low level output which means if it mee...

Page 11: ...en AUX output is 1 otherwise it will delay switching For example in mode 0 or mode 1 users continuously inputs a large amount of data and simultaneously performs mode switching At this time the switch...

Page 12: ...Type When M0 1 M1 0 the module works on Mode 1 Transmitting The condition of module starting data packet transmission and theAUX function equal to Mode 0 The only difference is that module will add w...

Page 13: ...s are sent in hexadecimal format The module returns version information and must be sent continuously 5 C4 C4 C4 Three C4s are sent in hexadecimal format and themodule will generate a reset and must b...

Page 14: ...l port mode of thetwo communication parties can be different 0 0 8N1 default 0 1 8O1 1 0 8 E1 1 1 8N1 equals to 00 5 4 3 TTLSerial port rate bps The baud rate of both parties can be different The seri...

Page 15: ...t thecall code for the corresponding time The receiver works in mode 2 which refers to thereceiver s listening interval wireless wake up and can only receive data from the module working in mode 1 0 0...

Page 16: ...r is well grounded and must be close to the digital part of the module and routed in the Bottom Layer Assuming that the module is soldered or placed in the Top Layer it is also wrong to randomly route...

Page 17: ...asy to damage Please check the power supply to ensure that it s within the recommended power supply or the module will be permanently damaged if it exceeds the maximum value Check the stability of the...

Page 18: ...mmunication process The inferior antenna often has a great impact on the communication system Therefore we recommend our antennas which have excellent performance and reasonable price to support our w...

Page 19: ...Chengdu Ebyte Electronic Technology Co Ltd E31 433T30D User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 13 Batch packaging method...

Page 20: ...ial version huaa 1 20 2018 01 29 Content updated huaa 1 30 2018 10 17 New model added huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you...

Reviews: