Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120A User Manual
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
1
Return
:
FA 38
6.5.4 Network operation instruction set
Open network
Send
:
F5 01 40 01 FF
Return
:
FC 40 00
Send
:
F5 01 40 01 FF
Return
:
FC 40 00
Leave Network
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Create network
Send
:
F5 01 40 03 FF
Return
:
FC 40 00
Send
:
F5 01 40 03 FF
Return
:
FC 40 00
Start Touchlink
Send
:
F5 01 40 04 FF
Return
:
FC 40 00
Send
:
F5 01 40 04 FF
Return
:
FC 40 00
6.6 HEX Parameter description
6.6.1
System transmitting mode
mode
:
0x00 Broadcast
(
default
);
0x01 (need to configure the target group number in configuration mode first);
0x02 Transparent transmission on short address (need to configure the target short
address in configuration mode);
0x03 transparent transmission on long address (need to configure the target long
address in configuration mode);
0x04 protocol on short address (the first two bytes in the transmission mode are the
short address of the target device network);
0x05 protocol multicast (the first byte in the transmission mode is the target network group
number);
6.6.2 Receiving data output mode
mode
:
0x00 transparent transmission
(
default
);
0x01 data+short address
;
0x02 data+long address
;
0x03 data+RSSI;
0x04 data+short RSSI
;
0x05 data+long RSSI
;
Note: the maximum package length is 72
6.6.3 Network node type
dev_type
:
0x01 Coordinator
0x02 Router
0x03 End-device (default)