Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10 User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
4-17
For
example
Request
:
02 C0 09
Respond
:
0B 40 09 112233445566 0004 03
Notes
:
1
、
Suitable for E104-BT10-G
2
、
Return MAC of networking device and assigned unicast address and element
numbers
11.Baud rate configuration
Operation code
Parameter
Request
0x0E
Baud rate serial number to be configured
(
range:
0x00~0x07
)
Respond
0x0E
Return the current baud rate serial number
For
example
Command
Baud rate serial number notes
03 C0 0E xx
Xx is baud rate serial number to be configured
(
0x00~0x07
)
00
:
230400
01
:
128000
02
:
115200
03
:
76800
04
:
57600
05
:
19200
06
:
9600
07
:
4800
Notes
:
1
、
Suitable for E104-BT10-G and E104-BT10-N
2
、
For example 3 C0 0E 02
,
when succeed, return 03 40 0E 02, if exceed range, return
03 40 0E FF
12. To read baud rate
Operation code
Parameter
Request
0x0F
/
Respond
0x0F
Return the current baud rate serial number
For
example
Command
Return
Notes
02 C0 0F
03 40 0F xx
Xx is baud rate number
00
:
230400
01
:
128000
02
:
115200
03
:
76800
04
:
57600
05
:
19200