background image

Chengdu Ebyte Electronic Technology Co., Ltd

E104-BT10 User Manual

Copyright ©2012–2019

C

hengdu Ebyte Electronic Technology Co., Ltd

4-26

See details from

3.3

Transmitting

08 c2 0002 11223344AA

Receiving

09 0A 42 0001 FFFF 11223344AA

6

FAQ

6.1 Communication range is too short

The communication distance will be affected when obstacle exists.

Data lose rate will be affected by temperature, humidity and co-channel interference.

The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground.

Seawater has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.

The signal will be affected when the antenna is near metal object or put in a metal case.

Power register was set incorrectly, air data rate is set as too high (the higher the air data rate, the shorter the
distance).

When the power supply at room temperature is lower than the recommended low voltage, the lower the voltage is,
the lower the transmitting power is.

6.2 Module is easy to damage

Please check the power supply and ensure it is within the recommended range. Voltage higher than the peak will
lead to a permanent damage to the module.

Please check the stability of power supply and ensure the voltage not to fluctuate too much.

Summary of Contents for E104-BT10

Page 1: ...E104 BT10 User Manual TLSR8269F512 UART SMD SIG Mesh Module ...

Page 2: ...le 4 1 4 Model 4 2 Specific instruction 4 2 1 Networking introduction 4 2 2 Node networking process and status indication 4 2 3 Networking whitelist 4 2 4 Network exception and processing 4 2 5 Remove nodes 4 3 Data format 4 3 1Parameter configuration 4 3 2 SIG Message 4 3 3 Transparent transmission 5 Quick start 5 1 Restore factory setting 5 2 Enter network 5 3 SIG Message 5 4Transparent transmis...

Page 3: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT10 User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 About us ...

Page 4: ...ports 80 bytes conforms to sig standard HSL H Hue S Saturation L lightness model one click implementation of the lighting control application scenario Ideal for IoT information collection large scale networking communication scenarios smart home applications etc 1 2 Features With PCB antenna transmission distance in open and clear air is up to 50 meter Max TX power of 8dbm can be configured to dif...

Page 5: ... 1 9 3 3 3 6 3 3 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 80 Frequency MHz 2400 2483 5 ISM band Power consumption Transmitting current mA 29 Instant power consumption Receiving current mA 29 Transmitting power dBm 8 0 Receiving sensitivity dBm 88 92 97 Air data rate is 1Mbps Communicati on rate GFSK bps 1M Main parameter...

Page 6: ...tput Corresponds to green indicator of SIGMESH HSL 3 PE1 PWM output Corresponds to red indicator of SIGMESH HSL 4 DM GPIO 5 DP GPIO 6 PA0 GPIO 7 PA1 GPIO 8 PA3 GPIO 9 PA4 GPIO 10 PA7 GPIO 11 SWS Program download interface 12 PB1 GPIO 13 PB4 output Networking indicator when succeed pin outputs high level 14 PB5 GPIO 15 PB6 PWM output Corresponds to blue indicator of SIGMESH HSL 16 PB7 GPIO 17 TXD o...

Page 7: ...ng and other parts with large electromagnetic interference High frequency digital routing high frequency analog routing and power routing must be avoided under the module If it is necessary to pass through the module assume that the module is soldered to the Top Layer and the copper is spread on the Top Layer of the module contact part well grounded it must be close to the digital part of the modu...

Page 8: ...td E104 BT10 User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 4 7 3 2 Circuit Diagram As shown to connect VCC GND TX RX then communication test can be conducted 4 Function introduction MESH network is shown as below ...

Page 9: ...t directly send data to the C module If module B is placed between the A module and the C module then the data will be repeatered by B and then received by C Module A needs to send data to the entire network Modules B C D and E need to receive data from A Then A module sends data by broadcast address 0XFFFF If the A module needs to send the specified data to the E module just fill in the address o...

Page 10: ...s from Mesh Profile3 86 4 1 3 Device role In SIG MESH protocol roles include node low power node relay node friend node proxy node Related functions are as explained below Node An edge node in the entire mesh network It has the ability to receive and transmit data but cannot work as a repeater Low power node Low power nodes due to the existence of the friend node the low power nodes do not need to...

Page 11: ... applies to the fact that two nodes send and receive messages to each other but without relay capability data packets cannot be forwarded 2 ADV Lower power That is a low power broadcast connection Used to send and receive data packets between the low power node and the friend node On this connection the low power node will initiate a request to establish a connection with the friendship and query ...

Page 12: ...ay have multiple addresses However a model in each device can only have one address but different models can be bound to one address in the subsequent mesh network communication process The device is relying on this address to find other devices E104_BT10 G is for the Provision role E104_BT10 N is for the node role 4 2 Specific instruction 4 2 1 Networking introduction E104_BT10 includes E104_BT10...

Page 13: ...or will go out The serial port will return the error code for assigning netkey failure see details from 3 1 and terminate the networking process Step 4 Bind Appkey The timeout period for binding the APPkey is 10 seconds If the APPkey is successfully bound within 10 seconds the serial port will return data in the following format The entire network can be used normally If the binding of appkey fail...

Page 14: ...4 3 Data format All data exchanged by the serial port including parameter configuration network control and data transparent transmission meet the following format requirements Any remaining data will be considered invalid and the module will not respond The parameter configuration is used for parameter configuration of the current module the SIG message is a standard mesh control message defined ...

Page 15: ...445566 Respond 12 40 00 11223344556677889900112233445566 Notes 1 suitable for E104 BT10 G 2 After configuration the system will restart once 2 To read NetKey Operation code Parameter Request 0x01 Respond 0x01 Return configured 16 bytes of NetKey data For example Request 02 C0 01 Respond 12 40 01 11223344556677889900112233445566 Notes This is for reading configured NetKey 3 AppKey configuration Ope...

Page 16: ...tion Operation code Parameter Request 0x04 Configure the unicast address for networking next time 2 bytes Respond 0x04 Return the currently configured unicast address for networking 2 bytes little end mode For example Request 04 C0 04 0007 Respond 04 40 04 0700 Notes 1 Suitable for E104 BT10 G 2 Configure the unicast address for networking next time 6 To read networking address Operation code Para...

Page 17: ...er to be deleted 1 byte Respond 0x07 Serial number MAC address of deleted device For example Request 03 C0 07 00 Respond 33 40 07 00 1234567890AB 00 00 00 00 means space for unbound MAC Notes 1 Suitable for E104 BT10 G 2 Return deleted serial number and MAC 9 To read networking filter Operation code Parameter Request 0x08 Respond 0x08 Return started serial number and joined MAC For example Request...

Page 18: ... Respond 0x0E Return the current baud rate serial number For example Command Baud rate serial number notes 03 C0 0E xx Xx is baud rate serial number to be configured 0x00 0x07 00 230400 01 128000 02 115200 03 76800 04 57600 05 19200 06 9600 07 4800 Notes 1 Suitable for E104 BT10 G and E104 BT10 N 2 For example 3 C0 0E 02 when succeed return 03 40 0E 02 if exceed range return 03 40 0E FF 12 To read...

Page 19: ...0x12 Return configured power number For example Command Notes 03 C0 12 xx Xx is baud rate serial number to be configured 0x00 0x0A 00 8dBm 01 4dBm 02 0dBm 03 4dBm 04 10dBm 05 14dBm 06 20dBm 07 24dBm 08 28dBm 09 30dBm 0A 37bBm Notes 1 Suitable for E104 BT10 G and E104 BT10 N 14 To read power Operation code Parameter Request 0x13 Respond 0x13 Return the current power number For example Command Retur...

Page 20: ...st 02 C0 11 Respond 08 40 11 112233445566 Notes 1 Suitable for E104 BT10 G and E104 BT10 N 16 To restart device Operation code Parameter Request 0x14 Respond 0x14 Return operation status value For example Request 02 C0 14 Respond 03 43 14 00 Notes 1 Suitable for E104 BT10 G and E104 BT10 N 2 Status value 00 means succeed 17 Restore factory setting Operation code Parameter Request 0x15 Respond 0x15...

Page 21: ...itable for E104 BT10 G and E104 BT10 N 2 return unicast address of E104 BT10 N device in current network 4 3 2 SIG Message E104 BT10 supports SIG generic model and Lighting HSL model control refer to Mesh Profile and Mesh Model for details about SIG message SIG message follows format below Transmitting Command 1 byte Target address 2 byte Sig mesh message 0xC1 Main address of target device Request...

Page 22: ... send data within a single limit of 8 bytes the data format is as follows Transmitting Command 1 byte Target address 2 byte Data 0xC2 Main address of target device Valid data Receiving Command 1 byte Target address 2 byte Original address 2 byte Data 0x42 Main address of target device Main address of original device Valid data For example device 0001 send hex data 00112233445566778899 to device 00...

Page 23: ...debugging assistant to select the baud rate 115200bps 8 data bits no parity 1 stop bit select hexadecimal transmission The E104 BT10 G terminal edits and sends the Device Access command 02 C0 09 When E104 BT10 N enters the network successfully the indicator light is constant E104 BT10 G receives 0B 40 09EAFD CDBAFEAD 0007 03 where EAFDCDBAFEAD indicates successful network access equipment The MAC ...

Page 24: ...2 2019 Chengdu Ebyte Electronic Technology Co Ltd 4 23 5 3 SIG Message E104 BT10 G send command to turn on light generic onoff command see details from 3 2 see details from Mesh Model 3 2 1 2 Generic OnOff Set Transmitting 09 C1 0004 8202 01000000 Respond 08 41 0004 0001 8204 01 ...

Page 25: ...ight 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 4 24 E104 BT10 G send comand to turn off light generic onoff command see details from 3 2 see details from Mesh Model 3 2 1 2 Generic OnOff Set Transmitting 09 C1 0004 8202 00000000 Respond 08 41 0004 0001 8204 00 ...

Page 26: ...nt transmission 5 4 1 Broadcast transmission Device 0001 broadcasts 11223344AA in hex format See 3 3 input target address as FFFF all device in the network can receive data Transmitting 08 c2 FFFF 11223344AA Receiving 08 0A 42 0001 FFFF 11223344AA 5 4 2 Fixed point transmission For example Device 0001 sends 11223344AA in hex format to device 004 ...

Page 27: ...water has great ability in absorbing wireless radio wave so performance will be poor when testing near the sea The signal will be affected when the antenna is near metal object or put in a metal case Power register was set incorrectly air data rate is set as too high the higher the air data rate the shorter the distance When the power supply at room temperature is lower than the recommended low vo...

Page 28: ...d range for some parts are sensitive to humidity Please avoid using modules under too high or too low temperature 6 3 Bit error rate is too high When there are co channel signal interference nearby be away from interference sources or modify frequency and channel to avoid interference The clock waveform on the SPI is not standard Check whether there is interference on the SPI line The SPI bus shou...

Page 29: ...5 Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max Liquidous Temperature TL 183 217 Time tL Maintained Above TL 60 90 sec 30 90 sec Peak temperature Tp 220 235 230 250 Aveage ramp down rate Tp to Tsmax 6 second max 6 second max Time 25 to peak tempera...

Page 30: ... Size Package Interface Hz dBm m mm E104 BT10 TLSR8269F512 2 4G 8 50 19 13 SMD TTL Revision history Version Date Description Operator 1 0 2019 4 12 Initial Version About us Website www ebyte com Sales info cdebyte com Support support cdebyte com Tel 86 28 61399028 Ext 812 Fax 86 28 64146160 Address Innovation Center B333 D347 4 XI XIN road High tech district west Chengdu Sichuan China ...

Reviews: