Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT05 User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd
14
0
:
No parity;
1
:
Odd Parity;
2
:
even parity;
Set
:
AT+PARI=[para]
+OK
:
success
+ERR=[NUM]:error
Description: Restart takes effect, save when power off
5.5 Check current broadcasting status, turn on general broadcasting, IBeacon
broadcasting, turn off broadcasting
Command
Respond
Parameter
Request
:
AT+ADVEN?
+OK=[para]
Para:0
、
1
、
2 ASCII
0
:
Turn off the broadcast
1
:
General broadcasting
2
:
iBeacon broadcast
Set
:
AT+ADVEN=[para]
+OK
:
success
+ERR=[NUM]
:
error
Description: It takes effect after the connection is disconnected, save when power off
5.6 Request/Set broadcast data
(
Save when power off
)
Command
Respond
Parameter
Request
:
AT+ADVDAT?
+OK=[para]
Para:
ASCII
、
HEX
1
、
Length not more than 26 bytes
Set
:
AT+ADVDAT=[para]
+OK
:
success
+ERR=[NUM]
:
error
Description: The next broadcast will take effect
,
Save when power off
For example change to string “CDEBYT”
:
AT+ADVDAT=CDEBYT
5.7 Request/Set broadcast data(Do not save when power off)
Command
Respond
Parameter
Request
:
AT+ADVDAT1?
+OK=[para]
Para:
ASCII
、
HEX
1
、
Length is no more than 26
bytes
Set
:
AT+ADVDAT1=[para]
+OK
:
success
+ERR=[NUM]
:
error
Description
:
The next broadcast will take effect, do not save when power off, can be sent as a string or as a
hexadecimal
For example, change to a string “CDEBYT”
:
AT+ADVDAT=CDEBYT
5.8 Request/Set IBeacon Major broadcast data
Command
Respond
Parameter
Request
:
AT+IBCMAJOR?
+OK=[para1]
Para1
:
0000H~FFFFH
HEX
Set
:
AT+IBCMAJOR=[para1]
+OK
:
success