Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT05 User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd
21
5:-14dBm
6:-20dBm
7:-28dBm
8:-30dBm
9:-37dBm
Description: Be effective at once, save when power off
5.36 Request/Set sleep after disconnection
Command
Respond
Parameter
Request
:
AT+DISCSLEEP?
+OK=[para]
Para: 0
、
1 ASCII
0
:
Close
1
:
Open
Set
:
AT+DISCSLEEP =[para]
+OK
:
success
+ERR=[NUM]
:
error
Description: Be effective at once, save when power off
5.37 Get to sleep mode at once
Command
Respond
Parameter
Request
:
AT+SLEEP?
STA:sleep
None
Description :Be effective at once, if the broadcast is not turned off, the broadcast gap as the wake-up time will continue
broadcasting
5.38 Request/Set print status
Command
Respond
Parameter
Request
:
AT+LOGMSG?
+OK=[para]
Para: 0
、
1 ASCII
0
:
Close
1
:
Open
Set
:
AT+LOGMSG=[para]
+OK
:
success
+ERR=[NUM]
:
error
Description: Be effective at once, save when power off
5.39 Read IO0 input
Command
Respond
Parameter
Request
:
AT+ IO0?
+OK=[para]
Para: 0
,
1 ASCII
0
:
low level
1
:
High level
Description: Be effective at once, save when power off