Terminal
Connection description
AC, AC
Two terminals for AC power supply (output from AC
transformer)
+ACU
Positive terminal of battery
GND
Device ground,
common for
other input and output
TMP
Connection of monitoring sabotage switch (the
second switch contact connected to COM terminal).
IN1 to IN8
Signal inputs. Possible connection of detectors
contacts or alarm control panel outputs. COM
terminal is common for all inputs.
NC, NO,
C(OUT3)
Optional relay output connections. In this case use
OUT3 as relay C connector.
OUT1,OUT2,
OUT3
Type OC additional outputs. It may control external
device. Provides ground during activation.
+12V
Supply voltage output. Provides up to 200mA
NOTES:
OUT1, OUT2, OUT3 outputs can sink up to 100mA. Don’t short this output to
power supply because it can cause permanent damage of output.
Don’t connect power supply when GSM antenna isn’t connected, because it
can cause permanent damage of GSM/GPRS modem.
After careful connections examination a battery may be connected (to +AKU and
GND terminals) and then power may be switched on for transformer and
programming procedure of transmitter may begin (See chapter 6).