ALARM CONTROL UNIT 

 

CPX220NWB 

 

Installation and 

programming manual 

 

Version of the manual:   

 

 

v1.2 

Date of issue:   

 

 

 

2016.10.27 

Firmware version: 

 

 

 

2.6.3 

GPRS transmitter configurator version:   

1.3.64.3 

OSM server version: 

 

 

 

1.3.60.4 

 

Summary of Contents for CPX220NWB

Page 1: ...ONTROL UNIT CPX220NWB Installation and programming manual Version of the manual v1 2 Date of issue 2016 10 27 Firmware version 2 6 3 GPRS transmitter configurator version 1 3 64 3 OSM server version 1...

Page 2: ...l not be deemed to be providing any warranties either express or implicit including but not limited to any implied warranties of merchantability or fitness for a particular purpose unless it is requir...

Page 3: ...3 6 4 ADDRESSING DEVICES CONNECTED TO THE KEYPAD BUS 21 3 7 WIRELESS KEYPAD KP1W 22 3 7 1 ADDING KP1W TO THE SYSTEM 22 3 7 2 DESCRIPTION OF KEYPAD ELEMENTS 23 3 7 3 KEYPAD SPECIFICATION 24 3 7 4 KEYP...

Page 4: ...FAILURES HISTORY WITH SYSTEM DIODE 79 6 4 2 IGNORE ATS FAILURE 79 6 4 3 TURN AUTOMATIC OVERRIDE FOR FAILURE OFF 79 6 4 4 ACCESS TO ALARM AND FAULT MEMORY REQUIRES AUTHORIZATION 79 6 4 5 ALARMS AND INP...

Page 5: ...DS FOR MANAGING THE PARTITIONS ZONES AND OUTPUTS 114 10 CHANGE HISTORY 123 LIST OF DRAWINGS AND DIAGRAMS DRAWING 1 DESCRIPTION OF PCB ELEMENTS 11 DRAWING 2 DESCRIPTION OF SCREW TERMINALS OF THE CONTRO...

Page 6: ...e central unit is equipped with 3 outputs and 16 zones with the possibility to be divided into 2 partitions Dedicated KP16 LED keypad was designed in a modern discreet style Portable size large comfor...

Page 7: ...assign any number of zones to each of them KEYBOARD cooperation with LED keyboard KP16 ability to connect up to three keypads TRANSMISSION Transmission of signals through GPRS SMS module Encryption of...

Page 8: ...pad no sensors connected 120mA 1100mA 18VAC Average current consumption lack of external supply without keypad with keypad fully charged battery no sensors connected established connection with server...

Page 9: ...t with additional input FL 10 Wireless Flood Detector Programmers Description GD PROG CPX Controll Panel Programmer SP PROG Universal Programmer SP PROG BT Universal Programmer with Bluetooth module M...

Page 10: ...e keypad at the core diameter 0 5mm2 cannot exceed 200m 4 Install detectors and door and window reed relays Connect the installed elements with control unit For sample configuration of zones please re...

Page 11: ...al GSM range The control unit is compatible with GSM antenna with male SMA connector This type of antenna should be install sellotape on nonmetalic surface plastic glass etc in vertical position foto...

Page 12: ...iption of ERROR LED operation please refer to chapter 7 5 OK LED Green LED diode For the detailed description of OK LED operation please refer to chapter 7 6 CONF programming connector CONF IDC10 conn...

Page 13: ...X220NWB included two types of antennas internal and external dipole type 433MHz internal antenna Internal antenna can be used wherever required compact size and antenna provides appropriate coverage l...

Page 14: ...rnal antenna dipol type Antenna should be connected to GND and ANT connector regardings to the color on the endings of the wires Before screw the antenna remove plastic element from GND socket Correct...

Page 15: ...MANUAL 15 123 3 3 DESCRIPTION OF SCREW TERMINALS OF THE CONTROL UNIT NOTE Any assembly and installation works shall be carried out with power supply off and battery disconnected Drawing 2 Description...

Page 16: ...ally closed NC or normally open NO as well as with assigned parameters EOL NO or EOL NC using 2 2k resistors or with assigned double parameters DEOL NO or DEOL NC using 1 1k resistors Both resistor ty...

Page 17: ...ER MANUAL 17 123 3 5 SAMPLE CONNECTION OF SIGNALLING DEVICE 3 5 1 Internal signalling device without independent source of power supply Drawing 4 Sample connection of internal signalling device withou...

Page 18: ...ARM CONTROL UNIT INSTALLER MANUAL 18 123 3 5 2 External signalling device with independent source of power supply Drawing 5 Sample connection of external signalling device with independent source of p...

Page 19: ...nd control unit operation After first pressing any button the keypad is backlit After a few second idle time backlight gets automatically dimmed In order to make codes easier to remember buttons are m...

Page 20: ...normal operation it means that the line it is assigned to was disrupted Flashing LED means the zone was interlocked After activating service functions LEDs display data 7 Screw terminals The connector...

Page 21: ...ld choose the appropriate screws indywidually 5 Connect cables joining the keypad with the alarm control unit Keypad terminals marked KT KR KP KG shall be connected with KT KR KP KG terminals in the a...

Page 22: ...he wireless keypad KP1W uses one way transmission and cannot receive communication from the control panel Therefore we suggest to set one of the central panel outputs in arming disarming signalization...

Page 23: ...ns 0 9 buttons and as well as are intended for keypad and control unit operation After first pressing any button the keypad is backlit After a few second idle time backlight gets automatically dimmed...

Page 24: ...tion Power supply 1 battery CR123A 3V Working time 3 years Frequency of operation 433 92 MHz Communication range up to 500m open air Communication one way Average current consumption 30 A Operation te...

Page 25: ...as the battery is inside two LEDs for battery red one for transmission blue one and keys backlight will light up temporarily 5 Put together the front part of the case with the back one starting from t...

Page 26: ...cation The radio waves are attenuated by walls and other obstacles Lowest attenuation have wallboards and wooden frame Medium attenuation have light concrete and brick walls Reinforced concrete and me...

Page 27: ...CPX220NWB ALARM CONTROL UNIT INSTALLER MANUAL 27 123 Drawing 11 Signal loss through construction materials...

Page 28: ...ONS The wireless detectors should be located relative to the panel in such a way as to be on the same side of the control panel as the radio antenna and electronic components In this way you get the b...

Page 29: ...evant to a given option of the function on off Press 1 to 9 buttons to change the status of LED and the option it corresponds to Options 10 16 may be changed by long press the buttons 0 6 The installe...

Page 30: ...r the control unit s reset using configured parameters The device will exit test mode automatically after 5 minutes without pressing the buttons and system will restart 4 3 INSTALLER MENU After enter...

Page 31: ...ettings That function resets the settings to their default configuration accessible from the service mode level Additionally the function sets the default output options and default installer code The...

Page 32: ...ee access failures If this option is enabled the keypad will be blocked for 90 seconds after entering an invalid code three times After this period another lock will occur after entering a wrong code...

Page 33: ...ring number 00 will change the parameters for all zones in the system Y number of parameter related to a given zone 0 complex function the initiation of which configures the parameters listed below as...

Page 34: ...for zone 1 using complex functions zone 1 is to be set as immediate circuit in NC mode to be blocked after 8 violations and generate alarm when violated after arming with the 500ms sensitivity 4 3 7...

Page 35: ...n arm disarm o 7 chirp on arm disarm and signalling alarm 2 time of output activation in seconds DEC type parameter if 0 is set output will operate in bi stable mode It is possible to configure the ch...

Page 36: ...eter 4 alarm time in the partition in seconds DEC type parameter 5 partition options BIT type parameter o 1 Quiet signalling of time for entering during counting the time for leaving the buzzer in a k...

Page 37: ...sed Eg If the auto arming time is set to 2 30 and time was changed forward from 2 00 to 3 00 the control panel will not arm Examples a change of a single parameter assigning 1 2 3 zones to the first p...

Page 38: ...a sensor After selecting this option you can confirm deleting by pressing key or you can cancel function by pressing key 2 Add a sensor After selecting this option the sabotage button on the sensor h...

Page 39: ...ignal strength To return to line selecting menu press or To exit the function press or if no key has been selected 4 3 9 3 Delete all wireless sensors To remove all wireless sensors from the system en...

Page 40: ...remote control o 1 P300 remote control o 2 RC 10 remote control 4 The use to which the remote control is assigned 5 6 7 8 buttons functions o 0 no fuction o 1 arm o 2 disarm o 3 alarm o 4 silent alar...

Page 41: ...ttern XX Y where XX emergency button 01 fire 02 help 03 panic 00 all buttons above Y enable disable emergency button 0 disable emergency button 1 enable emergency button o 1 output 1 o 2 output 2 o 3...

Page 42: ...refused access to text messages Choice of installer s permissions can be accepted by pressing the button CPX220NWB can store up to 10 phone numbers and up to 32 text messages If for any reason the SM...

Page 43: ...PARTITION2 default partitions names they can be changed with the SETNAME command X Y partition states possibile values 0 disarmed 1 armed GETARMED ERROR command rejected by the system Setting the name...

Page 44: ...ption GETNAME PARTITION NR VALUE partition name GETNAME ERROR command rejected by the system Setting the phone number Command syntax XXXX SETTELNUM ID NUMBER Command description Setting the phone numb...

Page 45: ...k message description GETTELNUM ID NUMBER information about phone number GETTELNUM ERROR command rejected by the system Setting the content of text message Command syntax XXXX SETMESSAGE ID MESSAGE Co...

Page 46: ...tting the content of text message under the pointed index XXXX user code ID index of text possible values 1 to 32 Example 1234 GETMESSAGE 30 Feedback message GETMESSAGE ID MESSAGE or GETMESSAGE ERROR...

Page 47: ...es Each digit counting from the left represents an index of the phone number first digit for the first phone number second digit for the second number and so on 0 message will not be send to this numb...

Page 48: ...number assigned to the specified event XXXX user code EVENT a short name of the event possible event names are listed at the end of this chapter Example 1234 GETUSERSMS ARM1 Feedback message GETUSERSM...

Page 49: ...zones 1 16 ended INPUT1 TAMPER to INPUT16 TAMPER Sabotage of zones 1 16 INPUT1 TAMPEREND to INPUT16 TAMPEREND Sabotage of zones 1 16 ended INPUT1 LOCK to INPUT16 LOCK Bypass of zones 1 16 INPUT1 UNLO...

Page 50: ...BEGIN Help alarm started KEYPAD SILENTALARM BEGIN Panic alarm started KEYPAD FIRE END Fire alarm ended JAMMING BEGIN GSM jamming JAMMING END GSM jamming ended DETECTOR1 LOST to DETECTOR16 LOST Detect...

Page 51: ...serted before the configuration settings transmission is initiated In this case use either SIM cards with PIN code authorization deactivated or change the PIN code using a mobile phone before the card...

Page 52: ...ed settings you can use it for programming another equipment First indicate a directory where the file was saved then give the file name User can modify the received data In order to be effective the...

Page 53: ...onnector of the alarm control unit The connection is executed through a dedicated programming cable using RS 232 serial port To program the equipment or perform other activities i e read the settings...

Page 54: ...pl Enter the port on which analyser will listen to instructions e g 9000 Click Add button to confirm the setting The connection is saved and moved to the table From that moment the program will enable...

Page 55: ...ystem is installed with at least one GSM modem connected If the device is registered for the server serial number and SIM card number see OSM 2007 Manual you can use the connection via OSM Provided th...

Page 56: ...3 and then use it for other devices You can use that function after you define a type and parameters of the connection E g for local connection the following window is displayed where Connection type...

Page 57: ...uration with default values Upon confirmation the connection definition window will be displayed The operation is possible using local connection only After the operation is completed the equipment pa...

Page 58: ...the equipment Switch the power off and disconnect the programming cable or switch the programming device into DEBUG mode Insert SIM card Re connect the power supply The equipment is ready for operatio...

Page 59: ...e server in Equipment tab it will be marked green Start the software and define the options of the equipment for description please refer to chapter 7 Select Send function The window will appear where...

Page 60: ...on mode Depending on user s preferences the equipment can operate in one of 4 modes to be selected from a drop list GPRS SMS GPRS transmission TCP IP protocol in standard and in case of problems with...

Page 61: ...as often as in case of GPRS transmission is usually undesirable That parameter allows significant extension of interval between tests time in minutes or disabling that option 6 1 1 5 Telephone number...

Page 62: ...puter on which Communication server software is installed e g 89 123 115 8 The address can be given as a server s domain name e g modul gprs com In such a case at least one DNS server address is requi...

Page 63: ...ent will retry to connect with a server in case the previous attempt was unsuccessful 6 1 4 4 Number of attempts of establishing connection with a server You can define how many times the equipment wi...

Page 64: ...e changed via OSM 2007 Console In such case please send following Custom command SETPARAM 3 1 new_code where new_code should contain from 4 up to 7 digits 6 1 5 3 SIM Card PIN code Since the equipment...

Page 65: ...e maximum transmission security the data transmitted are encrypted using AES The option can be used for both GPRS and SMS transmissions In case encrypted transmission was selected you can enter own da...

Page 66: ...figuration types are available NO NC EOL NO EOL NC DEOL NO DEOL NC Wireless NC type input must be closed for the whole time Line interruption causes its induction NO type input remains open It activat...

Page 67: ...on of the zone event without the alarm In case of trigger when partition is armed it generates violation of the zone event and raises the alarm Interior delay the line can be used when keypad is not i...

Page 68: ...ll be generated which allows to inform the monitoring station about the problem with the line This lock will last until disarming If the input is selected as the Alarm after time for exit then Interlo...

Page 69: ...larm is generated 6 3 1 6 Alarm after time for exit When selected the alarm will be generated if the line remains violated when the time to exit is up When deselected alarm will NOT be generated in ab...

Page 70: ...vent the accidental transmissions from other detectors only one detector cover should be removed during the procedure of adding a new detector In order to add a wireless input click Add Device New win...

Page 71: ...waiting for a wirells signal to come User has to press for a while the tamper switch on the sensor CPX220NWB will detect the transmission and print sensor s type and ID To bind this sensor with the A...

Page 72: ...CPX220NWB ALARM CONTROL UNIT INSTALLER MANUAL 72 123 Sensor preferences can be set now in the Inputs tab You can choose the same options as for wired zones excluding sensitivity...

Page 73: ...eturn will be ignored 6 3 3 2 Entry Exit The parameter allows switching off the indication of time for entry exit displayed by KP16 keypad 6 3 3 3 Time for exit It is time for leaving the partition As...

Page 74: ...r each input line is available Interlocking after time for exit option If this option is active in the case of arming with violated zone after time for exit will be generated event about blocked zone...

Page 75: ...ommunication loss Output is activated when information transmission to server is not possible GSM jamming indicator Output is activated when jamming GSM Chirp The output is activated when arming 1 chi...

Page 76: ...changed only with remote command 6 3 5 Remote controllers Configurator allows adding and configuring remote controllers in the same way as it was done in the Wireless Inputs configuration In order to...

Page 77: ...rom Button 1 to Button 4 Remote controller can have less then 4 buttons in that case additional Button colums should be left with the None option selected NOTE The selected user number must be activat...

Page 78: ...unction key support Events associated with emergency buttons will be transmitted to monitoring station only if they are enabled in the Monitoring tab see item 6 6 6 3 6 2 Outputs User can choose which...

Page 79: ...Selecting this option turns off signaling a loss of communication with the server on KP16 keypad 6 4 3 Turn automatic override for failure off Selecting this option enables the system fault signal whe...

Page 80: ...ress event Each user has his own duress code NOTE Firmware versions older than 2 1 0 do not support the duress code Upgrading the Firmware to version 2 or newer one has to make sure that there are no...

Page 81: ...be selected in the writing options Users configuration changes can be made only via programming cable Users update is not possible remotely via GPRS 6 6 MONITORING That option allows determining whic...

Page 82: ...s Clear button to remove all checked signals Press Reverse to reverse the check into the opposite ones 6 6 1 2 SMS ON OFF In these columns you can check which signals are to be reported to the monitor...

Page 83: ...ents to monitoring station via GPRS SMS The data may become valuable information about device s work conditions though it may increase amount of bytes sent through GSM network It is possible to define...

Page 84: ...ly Available options are Restrict all Means no possibility of communication Allow all Means that communication is allowed from any telephone number Allow selected Means that communication is allowed o...

Page 85: ...m these listed telephone numbers You can define up to 5 numbers When Allow selected box is checked you receive access to an edit box Enter the subsequent numbers in the box and click Add button to mov...

Page 86: ...important mainly for economic reasons Check the Activate SMS restrictions check box to activate the access to information groups subject to restrictions SMS tests to server SMS events sent to server...

Page 87: ...6 7 2 Remote commands 6 7 2 1 Users remote management enable Selecting this option allows you to remotely configure user accounts...

Page 88: ...fy users about occurrence of certain events by text message Before sending the message may occur an additional attempt a voice call see item 6 8 4 Options In order to add user s number to the notifica...

Page 89: ...e has to typed in the Messages tab These messages can be later assigned to specific events in the Events tab Before sending the message may occur an additional attempt a voice call see item 6 8 4 Opti...

Page 90: ...he Message column select one of the messages defined before To assign a number to an event a corresponding column from Num 1 to Num 10 has to be checked From now on whenever this event occurs a text c...

Page 91: ...call the device sends an SMS message Sending a message to the first user the first defined phone number is followed by an attempt to call the next user and send a message And so on A voice call to a...

Page 92: ...CPX220NWB ALARM CONTROL UNIT INSTALLER MANUAL 92 123...

Page 93: ...one number can be composed of an empty sequence which means it is applicable to any telephone number Rules are processed in accordance with a pre defined sequence from the beginning to the end i e the...

Page 94: ...ters defining the equipment s response after leaving GSM network You can define after what time from the moment the connection was lost the equipment shall initiate activities aiming at its restoratio...

Page 95: ...nd is defined in minutes Then define what activity shall be initiated by the equipment Select by checking an appropriate box at the response description Modem reset Device reset In case the equipment...

Page 96: ...ow the equipment will operate under the control of a new firmware NOTE The firmware update procedure shall be carried out with special care as improperly performed operation can prevent the correct op...

Page 97: ...quipment The control unit has an event log memory where about 5 thousand technical events can be recorded You can review the events history via GPRS and RS232 connection In the second situation first...

Page 98: ...CPX220NWB ALARM CONTROL UNIT INSTALLER MANUAL 98 123...

Page 99: ...ashing green LED 1 8 blinks The operation mode of the equipment is indicated by green LED which goes on for 2 seconds after the range is indicated In case the LED does not go on for 2 seconds after th...

Page 100: ...ootloader remains in the equipment and repeated equipment programming is possible Description LEDs OK green ERROR red STATUS yellow No software in the equipment Software update Decryption of firmware...

Page 101: ...he control panel The battery capacity should be sufficient to operate the system without a power supply for 12 hours In the GPRS Transmitters Configurator see item 6 4 or in the installer menu see ite...

Page 102: ...arms is available only after user code has been entered information about alarms memory is available only after user code has been entered information about failures is available only after user code...

Page 103: ...les below The newly configured parameter will be taken into account when the device will need to use it there is no need to restart the unit However there are parameters changes to which will be detec...

Page 104: ...ress Limitations Data length to 31 characters can be changed by ATS only Description Sets the OSM server address with which the device exchanges data Server_address can be given in the domain format e...

Page 105: ...e zone 1 bit 2 the zone 2 etc If the zone is impaired the bit is set Examples RLIMIT 6 Removes blocade from zone 1 and zone 2 RLIMIT 2 Removes blocade from zone 1 9 1 1 9 DT Format DT YY MM DD hh mm L...

Page 106: ...etwork and re registering to GSM and GPRS network when you restart the device and modem 9 1 2 4 DESC Format DESC Limitations Can be executed by ATS only Description Returns a string with a description...

Page 107: ...equal to 0 or 1 possible to execution only by ATS Description For x 0 it clears the queue of outstanding events to be sent to the OSM server This results in the loss of outstanding events the device...

Page 108: ...1 2 10 GETPARAM Format GETPARAM parameter Limitations Parameter is equal to APN or UN or PW or Server or PORT or SMS or SMSPERIOD or as id_typu index possible to execution only by ATS Description All...

Page 109: ...scription Verifies the user code specified as an argument of the command checks whether a user with the specified code exists Password is the password of the user id is the user number partitions are...

Page 110: ...r of the user whose authorizations are changed the partitions is the bit vector with the partitions to which the user should have the authorization bit 0 corresponds to the partition 1 bit 1 to the pa...

Page 111: ...user s password Id is the user identifier whose password is changed the password is his new password and the adminPassword is the system administrator password The command returns CPSETUSERPASSWORD E...

Page 112: ...ADDUSER EOK id partitions When a user is added CPADDUSER EALREADY_EXISTS id partitions If the specified user already exists CPADDUSER EID id partitions If the specified user ID is incorrect CPADDUSER...

Page 113: ...through an encrypted way you do not need to know the administrator password the user id 0 The command needs the option Allow remote user management to be set active in the Configurator Can be executed...

Page 114: ...to the tamper keypad 1 bit 2 corresponds to the tamper keypad 2 bit 3 corresponds to the tamper keypad 3 bit 7 corresponds to the alarm from remote controls zoneTampers is a bit vector indicating the...

Page 115: ...a bit vector indicating detectors power failures in wireless detectors means low battery in wireless detectors Bit 1 counting from 0 corresponds to the zone 1 bit 16 corresponds to the zone 16 partiti...

Page 116: ...failures of power supply outputs Bit 0 means the output KPOUT bit 1 means the output AUX1 bit 2 means the output AUX2 powerInFailures is a bit vector informing about the failures of power supply Bit...

Page 117: ...ctor is optional It means that partitions in the bit vector will be armed in stay mode It is not allowed to change arm mode of an already armed partition system will reject an attempt of arming in sta...

Page 118: ...al to zero has no sense since it does not change anything if the partitions is 0 the user s password is not checked and the status returned by the command is equal to EOK Password is the code of the u...

Page 119: ...nts to block Bit 1 counting from 0 means the zone 1 Sending a command with the argument of zones equal to 0 has no sense since it does not change anything Password is the system administrator or user...

Page 120: ...bit vector indicating the zones which one wants to unblock Bit 1 counting from 0 means the zone 1 Sending the commands with the argument of zones equal to 0 has no sense since it does not change anyth...

Page 121: ...is the system administrator or user password Returns a list of zones assigned to the partition in the format CPPARTITIONSGETZONES P1Zones P2Zones Where P1Zones P2Zones are the bit vectors indicating...

Page 122: ...em dministrator or user password Returns a list of outputs assigned to the partition in the format CPPARTITIONSGETOUTPUTS P1Outputs P2Outputs Where P1Outputs P2Outputs are the bit vectors indicating w...

Page 123: ...e Version Firmware Description 2016 08 29 i1 0 2 5 2 First version of the manual 2016 10 21 i1 1 2 6 2 Added information about smoke detector SD 20 and wireless keypad KP1W 2016 10 27 i1 2 2 6 3 Added...