CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
59 / 106
time for entrance to a particular partition. The system should be disarmed before
the expiration of programmed time in order not to trigger the alarm.
24h burglary
– that line causes immediate alarm irrespectively of whether the
system is armed or not.
Arming/disarming
– the line can be used for arming or disarming the system.
In case the line is activated with the system disarmed, the partition assigned to
the line is armed. In case the line is activated with the system armed, the partition
assigned to the line is disarmed.
24h tamper
– the line can be used for connecting tamper/sabotage circuits. In
case of trigger when partition is disarmed, it raises the fault. In case of trigger
when partition is armed, it raises the alarm.
Interior delay
– the line can be used when keypad is not in the first partition
which could be triggered during access to the keypad. In case of the interior delay
partition is triggered, system checks if time for enter is counting. If yes, the line is
treated as delay line. If not, the lien is treated as instant line.
24H burglary silent
– sends a report to the central station but provides no
keypad display or sounding.
24H fire
– works like 24H burglary.