CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
35 / 106
Feedback message
description
PARTITION1:X, PARTITION2:Y - Information about
partitions arm/disarm state.
PARTITION1,PARTITION2 – default partitions names,
they can be changed with the SETNAME command
X,Y – partition states, possibile values:
0 – disarmed
1 – armed
GETARMED:ERROR – command rejected by the
system
Setting the name of partition
Command syntax
XXXX SETNAME=PARTITION,NR,VALUE
Command description
Acquiring the information which partitions are
armed/disarmed
XXXX – user code
NR – number of the partition, possibile values: 1 or 2
VALUE – new name of the partition
Example 1:
1234 SETNAME=PARTITION,1,Cellar
Example 2:
1234 SETNAME="PARTITION,2,Kids Room"
Feedback message
SETNAME::OK or SETNAME:ERROR
Feedback message
description
SETNAME::OK – command accepted
SETNAME:ERROR – command rejected by the system
Getting the name of partition