background image

Operating instructions

P2E076-AC06-01

Translation of the original operating instructions

If you have any other problems, contact ebm-papst.

5.1 Cleaning

NOTE
Damage to the device during cleaning.

Malfunction possible
→ Do not clean the device using a water jet or high-pressure

washer.

→ Do not use any cleaners containing acids,

bases or solvents.

→ Do not use any pointed or sharp-edged objects to clean.

5.2 Safety test

What has to
be tested?

How to test?

Frequency

Which
measure?

Check the
protective
casing against
accidental
contact for
damage and to
ensure that it is
intact

Visual inspection At least every

6 months

Repair or
replacement of
the device

Device for
damage

Visual inspection At least every

6 months

Replace device

Mounting the
connection lines

Visual inspection At least every

6 months

Fasten

Mounting of
protective
earth connection

Visual inspection At least every

6 months

Fasten

Check the
insulation of
the wires for
damage

Visual inspection At least every

6 months

Replace wires

Weld seams
for crack
formation

Visual inspection At least every

6 months

Replace device

Check the ball
bearings to
ensure they
are quiet, can
move easily
and are free of
play

Manual check
by turning the
rotor in shut-off
state

At least every
6 months

Replace
device in case
of noise,
difficulty of
movement or
clearance of
the bearings

Item no. 10615-5-9970 · Revision 68158 · Release 2010-11-29 · Page 9 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for P2E076-AC06-01

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...be ejected resulting in bodily harm Take appropriate safety measures 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise...

Page 3: ...5 Transport and storage conditions and chapter 3 2 Nominal data Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards...

Page 4: ...Product drawing All measures have the unit mm 1 Connection line silicone 4G 4x brass lead tips crimped Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 4 9 ebm papst Mulfingen GmbH Co KG B...

Page 5: ...e discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internal...

Page 6: ...e Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether t...

Page 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 8: ...and secure the latter from being switched on again Wait until the pump stops If the device remains out of use for some time e g when in storage we recommend switching the device on for at least two ho...

Page 9: ...sual inspection At least every 6 months Replace device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least...

Reviews: