background image

Operating instructions

P2E076-AC06-01

Translation of the original operating instructions

2. PROPER USE

The device is exclusively designed as a built-in device for moving
water according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.

Proper use also includes:

Pumping water.

Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter 3.2 Nominal data.

Minding the operating instructions.

Improper use

Using the device in the following ways is particularly prohibited and
may cause hazards:

Pumping water that contains abrasive particles.

Operating the pump in an explosive atmosphere.

Using the pump as a safety component or for taking on safety-related
functions.

Operation with completely or partially disassembled or modified
protective features.

In addition, all application options that are not listed under proper use.

Item no. 10615-5-9970 · Revision 68158 · Release 2010-11-29 · Page 3 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for P2E076-AC06-01

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...be ejected resulting in bodily harm Take appropriate safety measures 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise...

Page 3: ...5 Transport and storage conditions and chapter 3 2 Nominal data Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards...

Page 4: ...Product drawing All measures have the unit mm 1 Connection line silicone 4G 4x brass lead tips crimped Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 4 9 ebm papst Mulfingen GmbH Co KG B...

Page 5: ...e discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internal...

Page 6: ...e Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether t...

Page 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 8: ...and secure the latter from being switched on again Wait until the pump stops If the device remains out of use for some time e g when in storage we recommend switching the device on for at least two ho...

Page 9: ...sual inspection At least every 6 months Replace device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least...