3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Inlet ring with pressure tap (k-factor: 438)

2

Mounting position for vibration-absorbing elements, tightening torque max. 40 Nm

3

Cable diameter min. 5 mm, max. 13 mm; tightening torque 6 ± 0.9 Nm

4

Cable diameter min. 16 mm, max. 20.5 mm, tightening torque 6 ± 0.9 Nm

5

Tightening torque 3.5 ± 0.5 Nm

6

Attachment holes for FlowGrid (00630-2-2957 not included in scope of delivery)

7

Motor support plate
Installation position: Only base mounting, shaft horizontal (motor support plate must be vertical!).
Rotor on top or rotor on bottom on request
The drawing shows the dimensions only and does not represent the installation position

Item no. 55797-5-9970 · ENU · Change 277818 · Approved 2023-04-27 · Page 4 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G630-PW04-01

Page 1: ...ed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Page 2: ...have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DAN...

Page 3: ...nding or in IT power systems The device is to be used in networks with network quality characteristics as per EN 50160 Using the device only in stationary systems Performing all maintenance work Conve...

Page 4: ...torque 6 0 9 Nm 5 Tightening torque 3 5 0 5 Nm 6 Attachment holes for FlowGrid 00630 2 2957 not included in scope of delivery 7 Motor support plate Installation position Only base mounting shaft hori...

Page 5: ...validity the conformity must be confirmed again The product does not fall within the scope of Regulation EU 2019 1781 due to the exception specified in Article 2 2a motors completely integrated into a...

Page 6: ...ial environment If several devices are connected in parallel on the supply side so that the line current of the arrangement is in the range 16 75 A this arrangement conforms to IEC 61000 3 12 provided...

Page 7: ...g parts DANGER Electrical charge 50 C between phase conductor and protective earth connection after switching off supply with multiple devices connected in parallel Electric shock risk of injury Ensur...

Page 8: ...For asymmetrical power systems or if a phase fails the leakage current can increase to a multiple of the nominal value 4 2 6 Locked rotor protection Due to the locked rotor protection the starting cu...

Page 9: ...cs enable pin open or applied voltage 5 50 VDC disable bridge to GND or applied voltage 1 VDC reset function triggers software reset after a level change to 1 V KL 3 8 Din2 Digital input 2 Switching p...

Page 10: ...ng Either run through the resonant range as quickly as possible with speed control or find another remedy Operation with excessively high vibration levels can lead to premature failure The maximum per...

Page 11: ...e from supply and remove mechanical blockage Line voltage faulty Check line voltage restore power supply Attention The error message resets automatically Device restarts automatically without warning...

Page 12: ...aintenance intervals to the actual level of dust exposure 6 3 Safety inspection NOTE High voltage test The integrated EMC filter has Y capacitors The tripping current is exceeded when AC testing volta...

Page 13: ...tallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plasti...

Reviews: