background image

Operating instructions

G2S076-AA03-01

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC 2 x 0.25 mm², 2x tin-plated wire ends

2

Cable PVC AWG20, 1x tin-plated wire end (green/yellow)

Item no. 11285-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G2S076-AA03-01

Page 1: ...and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the elect...

Page 2: ...t accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can becom...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...dimensions in mm 1 Cable PVC 2 x 0 25 mm 2x tin plated wire ends 2 Cable PVC AWG20 1x tin plated wire end green yellow Item no 11285 5 9970 ENU Change 202174 Approved 2018 12 28 Page 4 10 ebm papst Mu...

Page 5: ...e designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface qualit...

Page 6: ...environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection...

Page 7: ...st connect the PE protective earth Connect the cables according to your application When doing so observe Chapter 4 4 Connection diagram Item no 11285 5 9970 ENU Change 202174 Approved 2018 12 28 Page...

Page 8: ...nstructions 4 4 Connection diagram L blue PE green yellow N brown Item no 11285 5 9970 ENU Change 202174 Approved 2018 12 28 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Page 9: ...BLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric s...

Page 10: ...hases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropri...

Reviews: