3.3  Technical description 

27  Leakage: <3,5 mA i.h.t. IEC 60990 

Mode: S1 

Direction of rotation: Clockwise, viewed toward rotor 

Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request 

Moisture: Condensation in motor and/or electronic housing must be avoided. 

Insulation class: B 

Condensation discharge holes: Rotor side 

Motor bearing: ball bearing 

Motor protection: Thermal overload protector (TOP) internally connected 

IP Class: IP55 

Protection class: I 

 

28  Technical features:  

 

 

Control input 0-10 VDC / PWM 

Output 10 VDC, Max. 10 mA 

Over-temperature protected electronics / motor  

Tacho output, open collector, 1 pulse pr. revolt 

Motor current limitation 

Softstart 

 

3.4  Mounting data 

Secure the fastening device against unintentional loosening. 

 

29  Perform electrical installations in accordance with 60204-1, especially device potential equalization connection 

and connections (60204-1 Section 8). 

30  Prevention of accidental start-up shall be carried out in accordance with the rules of ISO 14118 

31  Any emergency stop functions must meet the requirements of ISO 13850 

 

3.5  Electromagnetic compatibility 

       32    EMC emission: EN 61000-6-3 

EMC Immunity: EN 6100-6-2 

Harmonic power feature: EN 61000-3-2/3 

 

33  If several units are connected in parallel to the supply voltage so that the current here is in the level 16 - 75 A, 

then this arrangement is in accordance with. IEC 61000-3-12 so long that the short-circuit current Ssc at the 

connection point to the public grid is greater than or equal to 120 times the nominal consumption of the entire 

event. 

The installer, the Engineer or the Owner is responsible for ensuring, after dialogue with the supply network 

operator that the unit is only connected to a supply network with a short-circuit current value Ssc greater than or 

equal to 120 times the nominal consumption of the entire event 

 

 

-//- 

4. CONNECTION AND STARTUP 

4.1  Mechanical connection. 

34  CAUTION

 

Risk of cutting and crushing when removing device from packaging 

Carefully remove the device from the packaging by grasping hold of the frame. Never subject to any impact. 

Wear safety shoes and cut-resistant safety gloves. 

If the machine is put into operation without associated ducting and safety precautions, there is a risk of 

Summary of Contents for BoxFan BF700S-355RT01I2

Page 1: ...akes it resistant to various climate impacts Inside the box the fan is mounted on a warm galvanized sheet metal plate and this is accessed by removing the inspection hatch The fan itself is an EC fan...

Page 2: ...surface 5 1 10 Storage 5 1 11 Disposal 5 1 12 Transport 5 2 INTENDED USE 5 3 TECHNICAL DATA 6 3 1 Product drawing 6 3 2 Nominal Data 7 3 3 Technical description 8 3 4 Mounting data 8 3 5 Electromagnet...

Page 3: ...TION Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified actions are not taken 4 NOTE A potentially harmful situation can oc...

Page 4: ...free blowing or free suctioning and is not connected to ducts The protective net must be able to withstand the kinetic energy of an impeller part The unit is a built in component You the owner is res...

Page 5: ...he longest possible service life The unit must be stored in the temperature range 40o C to 80o C Avoid shocks and bumps When storing or installing the product must be positioned so that it cannot func...

Page 6: ...under this application 24 Moving air contaminated by dust e g extraction of sawdust Operation of the unit close to combustible materials or components Operation of the device in an explosive atmosphe...

Page 7: ...x static pressure 880 Pa 1 Nominal data in working point with max load at 230 VAC 26 Additional data PFC Passive LwA Sound effect 87 dB A 2 LpA Sound pressure at 1 m 76 dB A 2 LpA Sound pressure at 3...

Page 8: ...cordance with the rules of ISO 14118 31 Any emergency stop functions must meet the requirements of ISO 13850 3 5 Electromagnetic compatibility 32 EMC emission EN 61000 6 3 EMC Immunity EN 6100 6 2 Har...

Page 9: ...e a gap between the supply cable and the control cable when installing these in the application Provide adequate distance Recommendation distance 10 cm separate wiring 39 NOTE Water ingress into wires...

Page 10: ...asic insulation on supply side and reinforced insulation on control interface side 1 7 COM White 2 Status relay floating status contact common connection contact rating 250 VAC 2A AC1 min 10 mA basic...

Page 11: ...ominal supply voltage Start the device by changing the input signal 4 8 Switching off the device 46 Switching off the device during operation Switch off the device via the control input to protect it...

Page 12: ...Lower temp if possible Reset by reducing control signal to 0 VDC Impeller runs unevenly Imbalance in rotating parts Clean the unit and balance it properly If imbalance Is still present the unit is re...

Reviews: