ebm-papst BoxFan BF700S-355RT01I2 User Manual Download Page 3

ebmpapst Denmark ApS, Vallensbaekvej 21, 2605 Broendby 

+45 4363 1111 

[email protected] 

 

2019.08.01 – page 3 

 

Read these operating instructions carefully before starting work on the device. Observe the following warnings to prevent 

malfunctions or danger to persons. 

 

These operating instructions are to be regarded as part of the device. The device is only to be sold or passed on 

together with the operating instructions. 

-//- 

1. SAFETY REGULATIONS AND INFORMATION 

1.1  Hazard levels for warrnings 

These operating instructions use the following hazard levels to indicate potentially hazardous situations 

and important safety regulations: 

 

1. 

 

DANGER 

Indicates an imminently hazardous situation which will result in death or serious injury if the specified 
actions are not taken. Compliance with the instructions is imperative

2. 

WARNING 

Indicates a potentially hazardous situation which can result in death or serious injury if the specified 

actions are not taken. Exercise extreme caution while working.

 

3. 

CAUTION

 

Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to 

property if the specified actions are not taken.

 

4. 

NOTE

 

A potentially harmful situation can occur and, if not avoided, can lead to property damage.

 

1.2  Staff qualifications 

5. 

The device may only be transported, unpacked, installed, operated, maintained and otherwise used 

by suitably qualified, trained and authorized technical staff. 

Only authorized specialists are permitted to install the device, to carry out a test run and to perform 

work on the electrical installation. 

1.3  Basic safety rules 

 

6. 

The safety hazards associated with the device must be assessed again following installation in the 

final product. 

7. 

Note the following when working on the device: 

Do not perform any modifications, additions or conversions on the device without the approval of ebm-

papst.

 

1.4  Voltage 

 

8. 

Check the device's electrical equipment at regular intervals, including the potential equalization 

connection, cf. EN60204-1. 

Replace loose connections and defective cables immediately. 

9. 

 DANGER  

Electrically charged device.  

Risk of electric shock.  

When working on an electrically charged device, stand on a rubber mat. 

 

Summary of Contents for BoxFan BF700S-355RT01I2

Page 1: ...akes it resistant to various climate impacts Inside the box the fan is mounted on a warm galvanized sheet metal plate and this is accessed by removing the inspection hatch The fan itself is an EC fan...

Page 2: ...surface 5 1 10 Storage 5 1 11 Disposal 5 1 12 Transport 5 2 INTENDED USE 5 3 TECHNICAL DATA 6 3 1 Product drawing 6 3 2 Nominal Data 7 3 3 Technical description 8 3 4 Mounting data 8 3 5 Electromagnet...

Page 3: ...TION Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified actions are not taken 4 NOTE A potentially harmful situation can oc...

Page 4: ...free blowing or free suctioning and is not connected to ducts The protective net must be able to withstand the kinetic energy of an impeller part The unit is a built in component You the owner is res...

Page 5: ...he longest possible service life The unit must be stored in the temperature range 40o C to 80o C Avoid shocks and bumps When storing or installing the product must be positioned so that it cannot func...

Page 6: ...under this application 24 Moving air contaminated by dust e g extraction of sawdust Operation of the unit close to combustible materials or components Operation of the device in an explosive atmosphe...

Page 7: ...x static pressure 880 Pa 1 Nominal data in working point with max load at 230 VAC 26 Additional data PFC Passive LwA Sound effect 87 dB A 2 LpA Sound pressure at 1 m 76 dB A 2 LpA Sound pressure at 3...

Page 8: ...cordance with the rules of ISO 14118 31 Any emergency stop functions must meet the requirements of ISO 13850 3 5 Electromagnetic compatibility 32 EMC emission EN 61000 6 3 EMC Immunity EN 6100 6 2 Har...

Page 9: ...e a gap between the supply cable and the control cable when installing these in the application Provide adequate distance Recommendation distance 10 cm separate wiring 39 NOTE Water ingress into wires...

Page 10: ...asic insulation on supply side and reinforced insulation on control interface side 1 7 COM White 2 Status relay floating status contact common connection contact rating 250 VAC 2A AC1 min 10 mA basic...

Page 11: ...ominal supply voltage Start the device by changing the input signal 4 8 Switching off the device 46 Switching off the device during operation Switch off the device via the control input to protect it...

Page 12: ...Lower temp if possible Reset by reducing control signal to 0 VDC Impeller runs unevenly Imbalance in rotating parts Clean the unit and balance it properly If imbalance Is still present the unit is re...