background image

 

 

page 5 of 8 

 

CONNECTION AND COMMISSIONING

 

 
Connect mechanical parts 
 

 

CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 

 

Wear safety boots and cut-resistant 
gloves. 

 

 

 

NOTE 
Risk of damage to electronic 
components. 
 

 

Use ESD protective equipment when 
mounting. 

 
 
 

Connect electrical parts 
 
Connect to the mains after installation. 
 

 

DANGER 
Do not touch. Risk of fatal injury 
from electrical current. 
 

 

Ensure that the electrical lines are 
de-energized. 

 

Secure the operating voltage against 
switching on again. 

 

Never work on parts that are 
energized. Only allow skilled 
electricians to work on the product. 

 

 

DANGER 
Compliance with the electrical 
installation regulations 
 

 

Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 

 

 

CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 

 

Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 

 
 
NOTE 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 

 

Ensure the electromagnetic compatibility of the entire system. 

 
Ground fault interrupter GFI 
 

 

DANGER 

Electrical voltage 
 

 

As additional protection we 
recommend the installation of a 
RCD (residual current protective 
device), which is adequate for 
product, usage and application. 

 

If it is possible to touch the fan 
directly / indirectly, the installation 
must be protected by a grounding 
contact and the supply voltage of 
the fan by a residual current device 
(RCD / FI). 

Summary of Contents for ACi 4400 L

Page 1: ... making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 15 02 2018 Version 1 1 Article number 9203509513 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS POS...

Page 2: ...d adapting to the market requirements of the country in question When working at the product observe the following Do not make any changes to the product WARNING Impermissible high load Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the electrical equipment of the product Eliminate immedi...

Page 3: ...at is well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Clean the product carefully with a moist cloth without applying pressure to the rotor Do not use cleaning agents ...

Page 4: ...dismantled or manipulated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or water and th...

Page 5: ...tions Observe the connection regulations that are valid in your country e g fusing GFCI CAUTION Electrical voltage The product is a built in component and has no switch for disconnecting power Only connect the product to current circuits that can be switched off by a switch all poles disconnected When working on the product secure the system machine in which the product is installed against switch...

Page 6: ...ith the interface data Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions Ensure that the electrical interface data is adequately protected mechanical Find additional information in drawing or label Check connections NOTE ACmaxx and ACi fans are built in products and must not be earthed Connect product Check the product for visible damage an...

Page 7: ...nding interrupted Exchange product Motor is not rotating Ambient temperature too high Reduce ambient temperature if possible Impeller out of true Unbalance of rotating parts Clean product if still unbalanced after cleaning exchange product In case of further faults contact ebm papst Technical safety inspection What requires checking How to check Frequency Protection against accidental contact prot...

Page 8: ......