background image

 

 

page 4 of 8 

 

 

INTENDED USE

 

 
The product is designed exclusively as a built-in device for conveying 
air according to the technical data. 
Every use that is not in accordance with the intended purpose, is 
regarded as misuse of the product. 
On-site installations must comply with the mechanical, thermal and 
service life requirements, see Chapter 3, Technical Data. 
 
Intended use includes: 
 
-  Operating the product with all protective equipment 
-  Do not put the product into operation before it has been installed in 

the customer's application 

-  Observation of the operating manual 
 
Use for other than the intended purpose 
 
Using the product for the purposes mentioned below is prohibited and 
can be dangerous: 
 
-  Conveyance of air that contains abrasive particles. 
-  Conveyance of air that has a highly corrosive effect. 
-  Conveyance of air that has a high dust load, e.g. vacuuming 

sawdust. 

-  Conveyance of inflammable gases/particles. 
-  Contact with materials that can damage the product, e.g. acids, 

caustic solutions, solvents. 

-  Exposure to radiation that can damage product components, e.g. 

strong UV rays or thermal radiation. 

-  Operating during external vibration. 
-  Operating the product close to inflammable materials or 

components. 

-  Operating the product in an explosive atmosphere 
-  Use of the prouct as a safety component or for performing safety-

relevant functions. 

-  Operating in medical devices with life-sustaining or life-saving 

function if not validated together with ebm-papst. 

-  Operating in non-stationary systems, e.g. railway vehicles, aircraft 

and spacecraft if not validated together with ebm-papst. 

-  Operating with fully or partially dismantled or manipulated protective 

equipment. 

-  Operating the product under conditions other than those mentioned 

in the technical data. 

-  Furthermore, all fields of application not mentioned under intended 

use. 

 
An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product.

TECHNICAL DATA

 

 
Drawing, see annex 
 
Technical description 
Airflow direction 

Air outlet over struts 

Rotating direction looking 
at rotor 

Clockwise 

Frequency 

50 Hz / 60 Hz 

Nominal voltage 

100 V - 240 V 

Current consumption 

20 mA 

12 mA 

Power consumption 

1,1 W 

1,1 W 

Speed 

1.500 1/min 

1.500 1/min 

Max. free-air flow 

78 m3/h 

 

Mass 

0,275 kg 

Protection class 

built-in fan 

Max. torque when 
mounted across both 
mounting flanges 

Wire outlet corner: 50 Ncm 
Remaining corners: 80 Ncm 

Screw size 

ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 

 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 

-40 °C ... 80 °C 

-40 °C ... 75 °C 

 
Vibration and shock load 
 
The mechanical Vibration and Shock data for the product is available. 
If the operation of the product should take place in a sinusoidal 
vibration containing environment or fixing the product on sinusoidal 
vibrating surface, please contact our technical support. 
 
Do not operate your product in the resonance range. 

Summary of Contents for ACi 4400 L

Page 1: ... making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 15 02 2018 Version 1 1 Article number 9203509513 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS POS...

Page 2: ...d adapting to the market requirements of the country in question When working at the product observe the following Do not make any changes to the product WARNING Impermissible high load Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the electrical equipment of the product Eliminate immedi...

Page 3: ...at is well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Clean the product carefully with a moist cloth without applying pressure to the rotor Do not use cleaning agents ...

Page 4: ...dismantled or manipulated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or water and th...

Page 5: ...tions Observe the connection regulations that are valid in your country e g fusing GFCI CAUTION Electrical voltage The product is a built in component and has no switch for disconnecting power Only connect the product to current circuits that can be switched off by a switch all poles disconnected When working on the product secure the system machine in which the product is installed against switch...

Page 6: ...ith the interface data Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions Ensure that the electrical interface data is adequately protected mechanical Find additional information in drawing or label Check connections NOTE ACmaxx and ACi fans are built in products and must not be earthed Connect product Check the product for visible damage an...

Page 7: ...nding interrupted Exchange product Motor is not rotating Ambient temperature too high Reduce ambient temperature if possible Impeller out of true Unbalance of rotating parts Clean product if still unbalanced after cleaning exchange product In case of further faults contact ebm papst Technical safety inspection What requires checking How to check Frequency Protection against accidental contact prot...

Page 8: ......