30
Main menu: Installer (continued)
Sen-
sors
Sensor
selec-
tion
Floor sensor
Tile/stone
Room sensor
Tile/stone
Room limited
floor
Max. (overheating)
Preset to 30 °C
Adjustable 27
–
35 °C
Min. (comfort)
Preset to 5 °C
Adjustable (Off)
5
–
25 °C
Wood/laminate/
vinyl
Floor limit.
room
Max (room restriction)
Preset to 25 °C
Adjustable 20
–
27 °C
Tile/stone
wood/laminate/
vinyl
Sensor
type
NTC 2 kΩ
As a guide, the
current temper-
ature for each
sensor type is
displayed.
NTC 10 kΩ
NTC 12 kΩ
NTC 15 kΩ
NTC 22 kΩ
NTC 33 kΩ
NTC 47 kΩ
NTC 100 kΩ
Calibra-
tion
Floor sensor
If required
the respective
sensors can be
calibrated.
Room sensor
Important!
In rooms exposed to solar radiation (large
windows), we recommend the function
“room and floor thermostat”.
In rooms with wooden floors the function
“room and floor thermostat” must always
be used.